Khanolkar M M, Sirsat A V
Department of Biochemistry, Tata Memorial Hospital, Bombay.
Indian J Med Res. 1992 Apr;96:136-8.
Serum alpha-hydroxybutyrate dehydrogenase (HBDH) and lactate dehydrogenase isoenzyme (LDH-1) levels by two techniques viz., adsorption on DEAE Sephadex A-50 and by electrophoresis were estimated in healthy subjects and patients with testicular tumours. The correlation coefficient between HBDH and LDH-1 by adsorption technique was found to be r = 0.8. HBDH was found to have a value almost twice that of LDH-1 by adsorption and electrophoretic technique and the activity of LDH-1 obtained by two methods and of HBDH in normals and patients with testicular tumours could be converted using a factor of 0.557. The quantitative method used for determination of HBDH is reliable, accurate, simple and rapid and therefore has better value in a clinical setting than electrophoresis and adsorption techniques which are laborious and time consuming.
采用两种技术,即通过吸附于二乙氨基乙基葡聚糖A - 50和电泳法,对健康受试者和睾丸肿瘤患者的血清α - 羟丁酸脱氢酶(HBDH)和乳酸脱氢酶同工酶(LDH - 1)水平进行了测定。通过吸附技术测得HBDH与LDH - 1之间的相关系数为r = 0.8。通过吸附和电泳技术发现,HBDH的值几乎是LDH - 1的两倍,并且通过两种方法获得的正常人和睾丸肿瘤患者的LDH - 1活性以及HBDH活性可以使用0.557的系数进行换算。用于测定HBDH的定量方法可靠、准确、简单且快速,因此在临床环境中比电泳法和吸附技术具有更高的价值,后两种技术既费力又耗时。