Suppr超能文献

[腕管的高分辨率磁共振成像。解剖学关联]

[High-resolution MRI of the carpal tunnel. Anatomical correlations].

作者信息

Dion E, Oberlin C, Codanda R, Idy-Peretti I, Jolivet O, Dauge M C, Sarcy J J, Grellet J

机构信息

Service de Radiologie Centrale, Hôpital La Pitié, Paris.

出版信息

J Radiol. 1992 May;73(5):293-301.

PMID:1432907
Abstract

This anatomical study of the carpal tunnel compares magnetic resonance imaging sections and adult and fetal anatomical sections. The MRI studies were carried out in 12 normal controls. The use of an experimental high resolution module allows achieving as high a degree of spatial resolution as 0.13 mm2. The comparison of MR images with anatomical sections allows a very accurate analysis of the contents of the carpal tunnel, especially of the median nerve, of the flexor tendons and of the flexor retinaculum.

摘要

这项腕管的解剖学研究对比了磁共振成像切片以及成人和胎儿的解剖切片。对12名正常对照者进行了磁共振成像研究。使用实验性高分辨率模块可实现高达0.13平方毫米的空间分辨率。将磁共振图像与解剖切片进行对比,能够非常准确地分析腕管内容物,尤其是正中神经、屈肌腱和屈肌支持带。