Bloustine J, Berejnov V, Fraden S
Complex Fluids Group, The Martin J. Fisher School of Physics, Brandeis University, Waltham, Massachusetts 02454, USA.
Biophys J. 2003 Oct;85(4):2619-23. doi: 10.1016/S0006-3495(03)74684-0.
A method is presented for determining second virial coefficients (B(2)) of protein solutions from retention time measurements in size exclusion chromatography. We determine B(2) by analyzing the concentration dependence of the chromatographic partition coefficient. We show the ability of this method to track the evolution of B(2) from positive to negative values in lysozyme and bovine serum albumin solutions. Our size exclusion chromatography results agree quantitatively with data obtained by light scattering.