Falla Deborah, Jull Gwendolen, Dall'Alba Paul, Rainoldi Alberto, Merletti Roberto
Department of Physiotherapy, The University of Queensland, St Lucia, Brisbane, 4072 Queensland, Australia.
Phys Ther. 2003 Oct;83(10):899-906.
This study evaluated an electromyographic technique for the measurement of muscle activity of the deep cervical flexor (DCF) muscles. Electromyographic signals were detected from the DCF, sternocleidomastoid (SCM), and anterior scalene (AS) muscles during performance of the craniocervical flexion (CCF) test, which involves performing 5 stages of increasing craniocervical flexion range of motion--the anatomical action of the DCF muscles.
Ten volunteers without known pathology or impairment participated in this study.
Root-mean-square (RMS) values were calculated for the DCF, SCM, and AS muscles during performance of the CCF test. Myoelectric signals were recorded from the DCF muscles using bipolar electrodes placed over the posterior oropharyngeal wall. Reliability estimates of normalized RMS values were obtained by evaluating intraclass correlation coefficients and the normalized standard error of the mean (SEM).
A linear relationship was evident between the amplitude of DCF muscle activity and the incremental stages of the CCF test (F=239.04, df=36, P<.0001). Normalized SEMs in the range 6.7% to 10.3% were obtained for the normalized RMS values for the DCF muscles, providing evidence of reliability for these variables.
This approach for obtaining a direct measure of the DCF muscles, which differs from those previously used, may be useful for the examination of these muscles in future electromyographic applications.
本研究评估了一种用于测量颈深屈肌(DCF)肌肉活动的肌电图技术。在进行颅颈屈曲(CCF)测试时,从DCF、胸锁乳突肌(SCM)和前斜角肌(AS)肌肉检测肌电信号,CCF测试包括进行5个阶段的逐渐增加的颅颈屈曲活动范围——这是DCF肌肉的解剖学动作。
10名无已知病理或损伤的志愿者参与了本研究。
在CCF测试过程中计算DCF、SCM和AS肌肉的均方根(RMS)值。使用置于口咽后壁的双极电极记录DCF肌肉的肌电信号。通过评估组内相关系数和均数的标准化标准误(SEM)获得标准化RMS值的可靠性估计。
DCF肌肉活动幅度与CCF测试的递增阶段之间存在明显的线性关系(F = 239.04,自由度 = 36,P <.0001)。DCF肌肉标准化RMS值的标准化SEMs在6.7%至10.3%范围内,为这些变量的可靠性提供了证据。
这种获取DCF肌肉直接测量值的方法与先前使用的方法不同,可能对未来肌电图应用中这些肌肉的检查有用。