Modified anastomotic technique for 1 millimeter internal diameter polytetrafluoroethylene arterial grafts in the rat.

作者信息

Golding M J, Harris J P, May J

机构信息

Department of Surgery, University of Sydney, NSW, Australia.

出版信息

Microsurgery. 1992;13(6):304-12. doi: 10.1002/micr.1920130604.

Abstract

Reported patency rates after standard end-to-end anastomoses for microvascular prosthetic grafts have been inconsistent and usually disappointing. A modified anastomotic technique is described in which the prosthetic graft is invaginated inside the arterial lumen. In this study of 6 cm lengths of 1 mm internal diameter polytetrafluoroethylene femoro-femoral bypass grafts in the rat, 6 (40%) of 15 grafts with standard anastomoses were patent at 6 months compared to 28 (90%) of 31 grafts using the modified anastomotic technique (P < 0.001). With invagination of the prosthetic graft inside the arterial lumen, reliable high patency rates can be achieved with microvascular prostheses long enough for potential clinical applications.

摘要

据报道,微血管假体移植物采用标准端端吻合后的通畅率一直不一致,且通常令人失望。本文描述了一种改良的吻合技术,即将假体移植物内翻至动脉腔内。在这项对大鼠进行的内径1mm、长度6cm的聚四氟乙烯股-股旁路移植物的研究中,15个采用标准吻合的移植物中有6个(40%)在6个月时保持通畅,而采用改良吻合技术的31个移植物中有28个(90%)保持通畅(P<0.001)。通过将假体移植物内翻至动脉腔内,对于长度足以用于潜在临床应用的微血管假体,可以实现可靠的高通畅率。