Conventional integral-imaging systems utilize lenslet arrays with fixed focal lengths and aperture sizes. We propose a time-multiplexed integral-imaging method that enhances both the depth of focus and the resolution of a three-dimensional image by displaying it with an array of lenslets with different focal lengths and aperture sizes. The nonuniform lenslet parameters (focal lengths and aperture sizes) for our method are calculated. Our theoretical analysis indicates that significant improvements in both depth of focus and resolution can be obtained with the proposed technique.
传统的积分成像系统使用具有固定焦距和孔径大小的微透镜阵列。我们提出了一种时分复用积分成像方法,通过使用具有不同焦距和孔径大小的微透镜阵列来显示三维图像,从而提高焦深和分辨率。计算了我们方法中微透镜的非均匀参数(焦距和孔径大小)。我们的理论分析表明,所提出的技术可以在焦深和分辨率方面取得显著改进。