乳腺闪烁造影和乳腺X线摄影在复发性乳腺癌中的作用。使用ROC曲线评估它们的准确性。

The role of scintimammography and mammography in recurrent breast cancer. Evaluation of their accuracy using ROC curves.

作者信息

Kolasińska A D, Buscombe J R, Cwikła J B, Holloway B, Parbhoo S P, Davidson T, Hilson A J

机构信息

Department of Nuclear Medicine, Royal Free Hospital, London, UK.

出版信息

Nucl Med Rev Cent East Eur. 2001;4(2):77-82.

Abstract

BACKGROUND

With the increasing demand for breast conservation surgery, the probability of recurrent tumour within the breast increases. Traditionally x-ray mammography (XMM) was used to assess the post-surgical breast, but post-surgery and radiotherapy changes have reduced the accuracy of this method. Scintimammography (SMM) has also been proposed and appears to be more accurate than XMM.

MATERIAL AND METHODS

A total of 101 women received (Tc99m) MIBI SMM and 88 had a subsequent XMM. There were 142 sites suspected of loco-regional recurrence breast cancer. During the study the patients did not receive any treatment other then hormonotherapy. SMM was performed by the standard Diggles-Khalkhali method and XMM was performed using standard 2 views. Analysis was performed and the results of each type of imaging compared with histology. In the ROC curve analysis 5 points of certainty were used: from 1 being definitely normal to 5 being definitely cancer; grades 4 and 5 were counted as positive.

RESULTS

The overall sensitivity value of SMM was 84% and specificity was 85%, compared with a sensitivity of 52% for XMM and a specificity of 84%. Analysis of areas under ROC curves provides statistically significant difference between SMM and XMM (p < 0.05). Combining the two tests did not significantly improve the diagnostic accuracy of sequence imaging over SMM.

CONCLUSION

ROC curve analysis demonstrates that scintimammography should be the primary investigation in suspected local recurrence following breast conservation surgery.

摘要

背景

随着保乳手术需求的增加,乳腺内肿瘤复发的可能性也随之上升。传统上,乳腺钼靶X线摄影(XMM)用于评估术后乳腺情况,但术后及放疗引起的改变降低了该方法的准确性。乳腺闪烁显像(SMM)也被提出,且似乎比XMM更准确。

材料与方法

共有101名女性接受了(锝99m)甲氧基异丁基异腈SMM检查,其中88名随后接受了XMM检查。共有142个部位疑似局部复发性乳腺癌。在研究期间,患者除激素治疗外未接受任何其他治疗。SMM采用标准的迪格尔斯 - 卡尔哈利方法进行,XMM采用标准的双视图进行。进行分析并将每种成像类型的结果与组织学结果进行比较。在ROC曲线分析中使用了5个确定性点:从1表示肯定正常到5表示肯定为癌症;4级和5级计为阳性。

结果

SMM的总体敏感性值为84%,特异性为85%,而XMM的敏感性为52%,特异性为84%。ROC曲线下面积分析显示SMM和XMM之间存在统计学显著差异(p < 0.05)。将两种检查结合使用并没有比单独使用SMM显著提高序列成像的诊断准确性。

结论

ROC曲线分析表明,乳腺闪烁显像应作为保乳手术后疑似局部复发的主要检查方法。