Ruotsalainen Mirja, Heinämäki Jyrki, Taipale Krista, Yliruusi Jouko
Pharmaceutical Technology Division, Department of Pharmacy, University of Helsinki, Finland.
Pharm Dev Technol. 2003;8(4):443-51. doi: 10.1081/pdt-120024697.
The effects of an aqueous film coating process on the morphology and storage stability of hydroxypropyl methylcellulose-coated tablets containing a moisture-labile model drug (acetylsalicylic acid, ASA) were evaluated using an instrumented side-vented tablet pan coater. Coating parameters studied were inlet air absolute humidity 5 g/m3 and 12 g/m3, spraying air pressure 100 kPa and 500 kPa, pan air temperature 35 degrees C and 55 degrees C, and coating solution flow rate 2.2 g/min and 7.8 g/min. The surface roughness of the coatings was measured with a laser profilometer and the chemical hydrolysis of the model drug ASA with an UV-spectrophotometer. The film-coated tablets were stored at 25 degrees C/60% RH and 40 degrees C/75% RH for three months. The high absolute humidity of the inlet air increased the residual water content and surface roughness of the coated tablets. Using a lower coating solution flow rate, higher spraying air pressure and pan temperature the coatings were smooth and homogeneous. In both ambient and accelerated storage conditions, the roughness of the coatings and the hydrolysis of ASA increased, but this was independent of the film coating process. Uniform and smooth hydroxypropyl methylcellulose coatings can be achieved by improved control of process parameters related to the application of the coating solution and water evaporation of the tablet surface.
使用配备仪器的侧通风片剂包衣锅,评估了水性薄膜包衣工艺对含有水分敏感型模型药物(乙酰水杨酸,ASA)的羟丙基甲基纤维素包衣片的形态和储存稳定性的影响。研究的包衣参数包括:进口空气绝对湿度5 g/m³和12 g/m³、喷雾空气压力100 kPa和500 kPa、锅体空气温度35℃和55℃以及包衣溶液流速2.2 g/min和7.8 g/min。用激光轮廓仪测量包衣的表面粗糙度,并用紫外分光光度计测量模型药物ASA的化学水解情况。将薄膜包衣片在25℃/60%相对湿度和40℃/75%相对湿度下储存三个月。进口空气的高绝对湿度增加了包衣片的残余水分含量和表面粗糙度。使用较低的包衣溶液流速、较高的喷雾空气压力和锅体温度,包衣光滑且均匀。在环境储存和加速储存条件下,包衣的粗糙度和ASA的水解均增加,但这与薄膜包衣工艺无关。通过改进与包衣溶液施加和片剂表面水分蒸发相关的工艺参数控制,可以获得均匀光滑的羟丙基甲基纤维素包衣。