[Effect of re-utilization of cuprophan capillary dialysers with different liquids on their biocompatibility and effectiveness of elimination].

作者信息

Orłowski A, Szepietowski T

机构信息

Oddział Dializy Szpitala ZOZ, Lubaniu.

出版信息

Polim Med. 1992;22(1-2):59-72.

PMID:1461837
Abstract

In 22 patients cuprophane capillary dialyzers reutilized in turn with four sets of liquids were used four times (Andante type in 13 and TAF-12 in 9 patients). The degree of biocompatibility and efficiency of elimination of small molecules was evaluated. During four-time reuse of dialyzers reutilized with sodium hypochlorite and with formaldehyde a reduction of intra-dialysis leukopenia, granulocytopenia and thrombocytopenia was not stated in blood of the patients. Activation of the complement system measured with the quantity of decrease of C3c fraction of the complement in the patients blood after 20 minutes of dialysis reduced essentially only at the fourth reuse of dialyzers (p < 0.01). Creatinine clearance measured always one hour after starting of the dialysis, did not change in succeeding reuse of dialyzers. Reutilization of dialyzers with hydrogen peroxide solution and formaldehyde caused essential reduction of ++intra-dialysis leukopenia and neutropenia (p < 0.001). There was lack of changes in ++intra-dialysis thrombocytopenia. Activation of the complement system was reduced essentially only after the fourth reuse of dialyzers (p < 0.001), but was also essentially lower (p < 0.05) than with dialyzers reutilized with sodium hypochlorite and with formaldehyde. Creatinine clearance practically did not change and at the fourth reuse of dialyzers it decreased on the average by 1.8%. Reutilization with acetic acid already at the second reuse of dialyzers essential (p < 0.001) and deepened decrease of intradialytic leukopenia and neutropenia and the activation of the complement system in course of succeeding reuses. Intradialytic thrombocytopenia was subjected to vestigal, not essential decrease. Creatinine clearance lowered a little but not essentially. At the fourth reuse of dialyzers it was lower on the average by 3.6% than the initial one. Reutilization with Dialina (stabilized blend of peracetic, acetic acid and hydrogen peroxide solution) caused essential (p < 0.001) and, in course of further reuses, deepening of lowering of intradialytic leukopenia and neutropenia as well as the activation of the complement system already at the second reuse. At the same time at the second and fourth reuse of dialyzers reutilized with Dialina the activation of the complement system was essentially lower than reutilized with the other liquids (p < 0.02). At the fourth reuse intradialytic thrombocytopenia also lowered essentially (p < 0.01). Creatinine clearance lowered a little more than with other liquids and at the second reuse of dialyzers was lower on the average by 5.6%, and at the fourth reuse--by 6.7% in relation to the new dialyzers.(ABSTRACT TRUNCATED AT 400 WORDS)

摘要

在22例患者中,依次使用四组液体反复使用铜仿膜毛细血管透析器4次(13例使用安坦特型,9例使用TAF - 12型)。评估了生物相容性程度和小分子清除效率。在使用次氯酸钠和甲醛反复使用4次的透析器过程中,未发现患者血液中透析期间白细胞减少、粒细胞减少和血小板减少有所减轻。用透析20分钟后患者血液中补体C3c分数降低量来衡量的补体系统激活情况,仅在透析器第4次反复使用时才基本降低(p<0.01)。每次透析开始1小时后测量的肌酐清除率,在透析器后续反复使用中未发生变化。用过氧化氢溶液和甲醛反复使用透析器导致透析期间白细胞减少和中性粒细胞减少显著减轻(p<0.001)。透析期间血小板减少没有变化。补体系统激活仅在透析器第4次反复使用后基本降低(p<0.001),但也比用次氯酸钠和甲醛反复使用的透析器显著更低(p<0.05)。肌酐清除率实际上没有变化,在透析器第4次反复使用时平均降低了1.8%。在透析器第2次反复使用时用乙酸反复使用就导致显著(p<0.001)且在后续反复使用过程中透析期间白细胞减少和中性粒细胞减少以及补体系统激活进一步加深。透析期间血小板减少有轻微但不显著的降低。肌酐清除率略有降低但不显著。在透析器第4次反复使用时,其平均比初始值低3.6%。用Dialina(过氧乙酸、乙酸和过氧化氢溶液的稳定混合物)反复使用导致显著(p<0.001)且在进一步反复使用过程中,透析期间白细胞减少和中性粒细胞减少以及补体系统激活在第2次反复使用时就开始降低。同时,在用Dialina反复使用的透析器第2次和第4次反复使用时,补体系统激活比用其他液体反复使用的透析器显著更低(p<0.02)。在第4次反复使用时,透析期间血小板减少也显著降低(p<0.01)。肌酐清除率比用其他液体反复使用时降低得更多,在透析器第2次反复使用时平均比新透析器低5.6%,在第4次反复使用时比新透析器低6.7%。(摘要截短为400字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验