Suppr超能文献

阶段时长、样条函数与乳酸阈最小游泳速度。

Stage length, spline function and lactate minimum swimming speed.

作者信息

Ribeiro L, Balikian P, Malachias P, Baldissera V

机构信息

Faculty of Physical Education, Campinas State University, Campinas, SP, Brazil.

出版信息

J Sports Med Phys Fitness. 2003 Sep;43(3):312-8.

Abstract

AIM

Lactate minimum test (LMT) has become popular in running evaluation. This study analysed the influence of different stage lengths and determination methods on lactate minimum swimming speed (LMS) and its validity for maximal lactate steady-state speed (MLSS-S) assessment.

METHODS

Twelve male swimmers (19.7+/-1.6 years, 70.3+/-8.7 kg, 181.4+/-7.9 cm) randomly underwent 4-5 evaluations in a 2-week period. LMS was accessed by simple visualisation (SV) and spline function (SF) methods during 200 and 300 m stages LMT (LMT200 and LMT300, respectively), and MLSS-S was determined during constant speed 2000 m efforts.

RESULTS

Respectively, SV and SF provided LMS during LMT200 (1.31+/-0.12 m x s-1 and 1.32+/-0.10 m x sec-1) and LMT300 (1.28+/-0.11 m x sec-1 and 1.28+/-0.10 m x sec-1) which were not significantly different (p>0.05) from each other. However, LMS accessed during LMT200 were significantly greater (p<0.05) than MLSS-S (1.25+/-0.06 m x sec-1). In addition, significant relationships (r=0.79 to 0.98; p<0.05) were found between all studied speeds and lactate minimum values during LMT300 were not significantly different (p>0.05) from those found during LMT200 (5.4+/-2.2 and 5.5+/-2.2 mM vs 6.8+/-2.5 and 7.0+/-2.6 mM, respectively for SV and SF).

CONCLUSIONS

Our results suggest that LMS is not affected by different stage lengths and determination

METHODS

However, LMT300 results seems to provide a more accurate MLSS-S prediction, being adequate for swimmers evaluation.

摘要

目的

乳酸最低值测试(LMT)在跑步评估中已变得流行。本研究分析了不同阶段长度和测定方法对乳酸最低游泳速度(LMS)的影响及其对最大乳酸稳态速度(MLSS-S)评估的有效性。

方法

12名男性游泳运动员(19.7±1.6岁,70.3±8.7千克,181.4±7.9厘米)在2周内随机接受4 - 5次评估。在200米和300米阶段的LMT(分别为LMT200和LMT300)期间,通过简单可视化(SV)和样条函数(SF)方法获取LMS,并在2000米恒速运动期间测定MLSS-S。

结果

在LMT200期间,SV和SF分别提供的LMS为(1.31±0.12米/秒和1.32±0.10米/秒),在LMT300期间为(1.28±0.11米/秒和1.28±0.10米/秒),两者之间无显著差异(p>0.05)。然而,LMT200期间获取的LMS显著高于(p<0.05)MLSS-S(1.25±0.06米/秒)。此外,在所有研究速度之间发现了显著相关性(r = 0.79至0.98;p<0.05),LMT300期间的乳酸最低值与LMT200期间的相比无显著差异(p>0.05)(SV和SF分别为5.4±2.2和5.5±2.2毫摩尔/升与6.8±2.5和7.0±2.6毫摩尔/升)。

结论

我们的结果表明,LMS不受不同阶段长度和测定方法的影响;然而,LMT300的结果似乎能提供更准确的MLSS-S预测,适用于游泳运动员评估。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验