Wan X Steven, Zhou Zhaozong, Kennedy Ann R
Department of Radiation Oncology, the University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania 19104, USA.
Radiat Res. 2003 Dec;160(6):622-30. doi: 10.1667/3099.
The oxidation of 2'7'-dichlorofluorescin (DCFH) to 2'7'-dichlorofluorescein (DCF), a fluorescent DCFH oxidation product, is a highly sensitive indicator that is used to measure oxidative stress in cells. In the present study, a DCF assay has been adapted to quantify oxidative stress in human breast epithelial cell cultures after exposure to gamma rays. The results demonstrate that the sensitivity and specificity of the DCF assay is strongly influenced by the timing of DCFH diacetate (DCFH-DA) substrate loading in relation to radiation exposure and by the matrix in which the cells were loaded with DCFH-DA substrate. Under the conditions optimized in this study, the DCF assay is capable of detecting increased DCFH oxidation in cell cultures irradiated with gamma rays at a dose as low as 1.5 cGy. The increase in fluorescence was directly proportional to the radiation dose, which ranged from 0 to 2 Gy, and a minimal level of fluorescence was observed in sham-irradiated cells. These results indicate that the DCF assay optimized in this study is highly sensitive, linear and specific for measuring oxidative stress in irradiated cells.
2'7'-二氯荧光素(DCFH)氧化生成荧光性的DCFH氧化产物2'7'-二氯荧光素(DCF),这是一种用于测量细胞氧化应激的高灵敏度指标。在本研究中,一种DCF检测方法已被用于量化人类乳腺上皮细胞培养物在暴露于γ射线后的氧化应激。结果表明,DCF检测方法的灵敏度和特异性受到二乙酸酯形式的DCFH(DCFH-DA)底物加载时间与辐射暴露时间的关系以及加载DCFH-DA底物的细胞所处基质的强烈影响。在本研究优化的条件下,DCF检测方法能够检测到低至1.5 cGy剂量的γ射线照射的细胞培养物中DCFH氧化的增加。荧光增加与0至2 Gy的辐射剂量直接成正比,且在假照射细胞中观察到最低水平的荧光。这些结果表明,本研究中优化的DCF检测方法对于测量受照射细胞中的氧化应激具有高度敏感性、线性和特异性。