Suppr超能文献

频率编码梯度对正常成年垂体腺边缘可检测性及高度测量的影响。

The effects of frequency-encoding gradient upon detectability of the margins and height measurements of normal adult pituitary glands.

作者信息

Taketomi A, Sato N, Aoki J, Endo K

机构信息

Department of Diagnostic Radiology, Gunma University School of Medicine, 3-39-22 Showa-machi, 371-8511, Maebashi, Japan.

出版信息

Neuroradiology. 2004 Jan;46(1):60-4. doi: 10.1007/s00234-003-0981-5. Epub 2003 Nov 27.

Abstract

We investigated the effects of frequency-encoding gradient (FEG) upon detectability and height measurements of the normal adult pituitary gland. We obtained two sets of T1-weighted sagittal images of the pituitary gland from 70 adult subjects without known pituitary dysfunction using 1.5 tesla imagers; one with an inferior-superior FEG, and one with an anterior-posterior FEG. We classified the subjects into three types according to the distribution of fatty marrow in the clivus. Each set of images was assessed for pituitary height on midline sagittal images, and detectability of pituitary margins. Height measurements and detectability scores were evaluated for significant difference between the two FEGs. In subjects with fatty marrow in the clivus, there was significant difference between pituitary height measurements (P < 0.005) and pituitary margin detectability (P < 0.001). Care should be taken to image the pituitary gland using an anterior-posterior FEG.

摘要

我们研究了频率编码梯度(FEG)对正常成人垂体可检测性及高度测量的影响。我们使用1.5特斯拉成像仪,从70名无已知垂体功能障碍的成年受试者中获取了两组垂体的T1加权矢状位图像;一组采用上下方向的FEG,另一组采用前后方向的FEG。我们根据斜坡内脂肪骨髓的分布将受试者分为三种类型。在中线矢状位图像上评估每组图像的垂体高度及垂体边缘的可检测性。对两种FEG之间的垂体高度测量值及可检测性评分进行显著差异评估。在斜坡内有脂肪骨髓的受试者中,垂体高度测量值(P < 0.005)及垂体边缘可检测性(P < 0.001)之间存在显著差异。使用前后方向的FEG对垂体成像时应谨慎。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验