Yasunaga Yuji, Goto Toshihiko, Hisatome Takashi, Tanaka Ryuji, Yamasaki Takuma, Ochi Mitsuo
Department of Orthopaedic Surgery, Hiroshima University Graduate School of Biomedical Sciences, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
J Orthop Sci. 2003;8(6):818-22. doi: 10.1007/s00776-003-0710-2.
We studied 27 patients (31 joints) who underwent total hip arthroplasty (THA) using the thrust plate hip prosthesis (TPP) for osteonecrosis of the femoral head. The mean follow-up period was 56 months (range 38-72 months). Clinical evaluation by the Merle d'Aubigne and Postel system showed a significant improvement from a preoperative mean score of 8.1 to a final mean follow-up score of 16.6. Mechanical loosening developed about 1 year postoperatively in one joint with a bone defect. Grade 1 stress shielding was observed in four joints. Although indications for the TPP are restricted to certain cases, unlike the conventional intramedullary stem, much can be expected of TPP. It is an outstanding prosthesis for osteonecrosis of the femoral head of young patients in terms of bone preservation and physiological load transfer.
我们研究了27例(31个关节)因股骨头坏死接受使用推力板髋关节假体(TPP)进行全髋关节置换术(THA)的患者。平均随访期为56个月(范围38 - 72个月)。Merle d'Aubigne和Postel系统的临床评估显示,术前平均评分为8.1分,最终随访平均评分为16.6分,有显著改善。1例有骨缺损的关节术后约1年出现机械性松动。在4个关节中观察到1级应力遮挡。尽管TPP的适应证仅限于某些病例,但与传统的髓内柄不同,TPP有很大的潜力。就骨保留和生理负荷传递而言,它是年轻患者股骨头坏死的优秀假体。