Suppr超能文献

犬肩胛骨远端三分之一处横行截骨术单半管状钢板与双半管状钢板固定的体外力学评估

An ex vivo mechanical evaluation of single versus double semitubular plate fixation of a transverse distal-third scapular osteotomy in the dog.

作者信息

Mair Jacqueline J, Belkoff Stephen M, Boudrieau Randy J

机构信息

Department of Clinical Sciences, Tufts University School of Veterinary Medicine, North Grafton, MA 01536, USA.

出版信息

Vet Surg. 2003 Nov-Dec;32(6):580-4. doi: 10.1111/j.1532-950x.2003.00580.x.

Abstract

OBJECTIVE

To compare single versus double semitubular plate fixation for scapular body fractures.

STUDY DESIGN

Ex vivo mechanical study.

SAMPLE POPULATION

Eighteen paired cadaveric canine scapulae.

METHODS

Transverse scapular body osteotomies were created in the distal third of 18 pairs of scapulae. One scapula of each pair was repaired with a single plate, whereas the contralateral scapula was repaired with 2 plates. Initial strength and stiffness of the constructs were measured in 10 pairs of scapulae. Eight pairs of scapulae underwent cyclic loading and then were subjected to failure testing.

RESULTS

Double-plate fixation was significantly stronger (3,899 +/- 632 N) but not stiffer (614 +/- 130 N/mm) than the single-plate fixation (3,238 +/- 935 N and 537 +/- 202 N/mm, respectively). Cyclic loading variables were not significantly different between the 2 methods of fixation. After cyclic loading, double-plate fixation was significantly stronger (2,916 +/- 618 N) than single-plate fixation (2,347 +/- 495 N). There was no significant difference (P =.11) in stiffness between double- versus single-plate fixations: 734 +/- 247 N/mm and 595 +/- 139 N/mm, respectively.

CONCLUSIONS

Double-plate fixation was generally stronger and stiffer than single-plate fixation. Because all constructs failed at loads that greatly exceeded those estimated to occur clinically, any difference between the 2 methods of fixation probably is not clinically relevant.

CLINICAL RELEVANCE

Single-plate fixation may be of sufficient strength for fixation of scapular body fractures.

摘要

目的

比较单块与双块半管状钢板固定肩胛体骨折的效果。

研究设计

体外力学研究。

样本

18对犬尸体肩胛骨。

方法

在18对肩胛骨远端三分之一处制作横行肩胛体截骨术。每对中的一块肩胛骨用单块钢板修复,而对侧肩胛骨用两块钢板修复。在10对肩胛骨中测量固定结构的初始强度和刚度。8对肩胛骨进行循环加载,然后进行破坏试验。

结果

双钢板固定明显比单钢板固定更坚固(3899±632 N),但刚度无明显差异(分别为614±130 N/mm和537±202 N/mm)。两种固定方法的循环加载变量无明显差异。循环加载后,双钢板固定明显比单钢板固定更坚固(2916±618 N)。双钢板与单钢板固定的刚度无明显差异(P = 0.11):分别为734±247 N/mm和595±139 N/mm。

结论

双钢板固定通常比单钢板固定更坚固、刚度更大。由于所有固定结构在远远超过临床估计载荷的情况下失效,两种固定方法之间的任何差异可能在临床上不相关。

临床意义

单钢板固定可能对肩胛体骨折的固定具有足够的强度。