Morano Gina N, Seibyl John P
Molecular NeuroImaging, LLC, 60 Temple Street, Suite 8A, New Haven, CT 06510, USA.
J Nucl Med Technol. 2003 Dec;31(4):191-5; quiz 202-3.
The purpose of this article is to give a basic understanding of imaging setup, postprocessing procedures, and anatomy for brain SPECT. After reading the article, the nuclear medicine professional should be able to describe the normal anatomy of the brain; the localization of radiopharmaceutical complexes within the brain; good techniques for image acquisition; and the concepts of filtered backprojection, smoothing filters, and attenuation correction in reconstruction.