A simple analytical device has been developed for performing noninstrumental immunofiltration-based assay on a batch of samples. The device consists of membrane strips, with antibody-immobilized zones, attached to a polyethylene card. A moist filter paper placed between the membrane and the polyethylene card acts as the absorbent body. The device was used to estimate very low concentrations of aflatoxin B1 (AFB1) present in food samples by using an improved catalyzed reporter deposition (Super-CARD) method of signal amplification involving biotinylated tyramine (B-T) and avidin-horseradish peroxidase conjugate. 4-chloro-1-naphthol was used as the substrate for visualization. Semiquantitative results are obtained by visual comparison of the color intensity (inversely related to the analyte concentration) of a sample spot with those of reference standards. Quantitative estimation is possible by densitometric analysis (detection limit 0.25 pg/spot, 0.01 ng mL(-1)). Dilute samples can be assayed by in situ concentration with improved dose-response characteristics. A batch of 12 extracted samples can be analyzed in a single test card within 12 min. Spiked and contaminated samples of groundnut, corn, wheat, cheese, and chilli were analyzed without sample cleanup. The matrix interferences were eliminated by using appropriate dilution of the aqueous methanol extracts. Mean recoveries from different food samples were between 91 and 104%. The values obtained for infected corn and groundnut samples correlated well (R2=0.99) with the estimates by HPLC. The method is well-suited for visual screening of agricultural and food samples for AFB1 under field conditions.

摘要

已开发出一种简单的分析装置,用于对一批样品进行基于非仪器免疫过滤的检测。该装置由附着在聚乙烯卡片上的带有抗体固定区的膜条组成。置于膜和聚乙烯卡片之间的湿滤纸用作吸收体。通过使用一种改进的催化报告沉积(Super-CARD)信号放大方法,该方法涉及生物素化酪胺(B-T)和抗生物素蛋白-辣根过氧化物酶偶联物,来估计食品样品中存在的极低浓度的黄曲霉毒素B1(AFB1)。使用4-氯-1-萘酚作为底物进行显色。通过目视比较样品斑点与参考标准品的颜色强度(与分析物浓度成反比)获得半定量结果。通过光密度分析可以进行定量估计(检测限为0.25 pg/斑点,0.01 ng mL(-1))。稀释样品可通过原位浓缩进行检测,具有改进的剂量反应特性。一批12个提取的样品可在12分钟内在单个测试卡中进行分析。对添加了AFB1和受污染的花生、玉米、小麦、奶酪和辣椒样品进行分析时无需进行样品净化。通过对甲醇水提取物进行适当稀释消除基质干扰。不同食品样品的平均回收率在91%至104%之间。感染玉米和花生样品获得的值与通过高效液相色谱法(HPLC)的估计值相关性良好(R2 = 0.99)。该方法非常适合在现场条件下对农业和食品样品中的AFB1进行目视筛查。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验