Comparison of transducers and intraoral placement options for measuring lingua-palatal contact pressure during speech.

作者信息

Searl Jeffrey P

机构信息

Communication Disorders Department, Bowling Green State University, Bowling Green, OH 43403, USA.

出版信息

J Speech Lang Hear Res. 2003 Dec;46(6):1444-56. doi: 10.1044/1092-4388(2003/112).

Abstract

Two studies were completed that focused on instrumentation and procedural issues associated with measurement of lingua-palatal contact pressure (LPCP) during speech. In the first experiment, physical features and response characteristics of 2 miniature pressure transducers (Entran EPI-BO and Precision Measurement 60S) were evaluated to identify a transducer suitable for measuring LPCP during speech. The 2 transducers were comparable in terms of physical dimensions and most response characteristics. However, the Entran device was less affected by air temperature fluctuations, making it the more attractive option for speech LPCP measurement. In a second experiment, 3 methods of placing the Entran device in the mouth were compared. The 3 adhesion methods evaluated were (a) taping a transducer to the hard palate, (b) surface mounting on a mold of the palate, and (c) flush mounting on a mold of the palate. Directly taping the transducer to the alveolar ridge was the least acceptable option, as it resulted in changes in other aspects of speech production (consonant duration and centroid frequency of the burst/frication) suggesting that articulation was unduly altered. Direct taping was also rated as least acceptable by the speakers. Surface and flush mounting resulted in fewer changes in speech aerodynamic and acoustic parameters of /t/ and/s/ compared to the tape condition. Listener ratings also indicated less articulatory disturbance in the surface and flush mounting conditions compared to the tape condition. Surface mounting was technically easier than flush mounting and it allows for rapid repositioning of the transducer if needed.

摘要

完成了两项研究,重点关注与言语过程中舌腭接触压力(LPCP)测量相关的仪器和程序问题。在第一个实验中,评估了2个微型压力传感器(Entran EPI - BO和Precision Measurement 60S)的物理特性和响应特性,以确定适合测量言语过程中LPCP的传感器。这2个传感器在物理尺寸和大多数响应特性方面具有可比性。然而,Entran设备受气温波动的影响较小,这使其成为言语LPCP测量更具吸引力的选择。在第二个实验中,比较了将Entran设备放置在口腔中的3种方法。评估的3种粘贴方法分别是:(a)将传感器粘在硬腭上,(b)表面安装在腭模型上,(c)嵌入式安装在腭模型上。将传感器直接粘在牙槽嵴上是最不可接受的选择,因为这会导致言语产生的其他方面发生变化(辅音持续时间和爆破/摩擦的质心频率),表明发音受到了过度改变。直接粘贴也被说话者评为最不可接受。与粘贴情况相比,表面安装和嵌入式安装导致/t/和/s/的言语空气动力学和声学参数变化较少。听众评分也表明,与粘贴情况相比,表面安装和嵌入式安装条件下的发音干扰较小。表面安装在技术上比嵌入式安装更容易,并且如果需要,它允许快速重新定位传感器。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验