Suppr超能文献

新型实验性全瓷系统粘结前后边缘适合性的临床评估

Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation.

作者信息

Wolfart Stefan, Wegner Stefan Martin, Al-Halabi Adham, Kern Matthias

机构信息

Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian Albrechts University, University Hospital Schleswig-Holstein, Campus Kiel, Germany.

出版信息

Int J Prosthodont. 2003 Nov-Dec;16(6):587-92.

Abstract

PURPOSE

The purpose of this in vivo study was to evaluate the marginal fit of inlay and crown abutments for fixed partial dentures (FPD) made from a new all-ceramic material.

MATERIALS AND METHODS

Sixteen patients were selected for the study. After abutment preparation, impressions were made and master dies were fabricated. FPDs were made with the experimental heat-pressed lithium-disilicate glass-ceramic following the manufacturer's recommendations. At random, one abutment of each FPD was chosen for evaluation (11 crown and 8 inlay abutments). Impressions of the restoration margins were taken before and after adhesive cementation. Replicas of the abutment margins were investigated by SEM. The marginal discrepancies were evaluated in sections of 200 microm. The highest value of each section was applied, and the mean of all sections of each replica was used for statistical analysis.

RESULTS

The median of the marginal discrepancies before cementation was 96 microm for crowns and 89 microm for inlays. After adhesive cementation, the median increased for crowns to 130 microm and for inlays to 92 microm, a significant increase in the marginal discrepancies caused by cementation for crowns, but not for inlays. There were no significant differences between the discrepancies of crowns and inlays before or after cementation.

CONCLUSION

The maximum marginal discrepancies found in this study were between 50 and 265 microm before cementation and between 70 and 285 microm after cementation, with no significant differences between the means for crowns and inlays. Adhesive cementation caused a significant increase of the marginal discrepancies for crown, but not inlay, abutments.

摘要

目的

本体内研究的目的是评估由一种新型全瓷材料制成的固定局部义齿(FPD)嵌体和冠基牙的边缘适合性。

材料与方法

选择16名患者进行研究。基牙预备后,制取印模并制作工作模型。按照制造商的建议,用实验性热压二硅酸锂玻璃陶瓷制作FPD。随机选择每个FPD的一个基牙进行评估(11个冠基牙和8个嵌体基牙)。在粘结水门汀前后制取修复体边缘的印模。通过扫描电子显微镜(SEM)研究基牙边缘的复制件。在200微米的切片中评估边缘差异。应用每个切片的最高值,并将每个复制件所有切片的平均值用于统计分析。

结果

粘结前冠的边缘差异中位数为96微米,嵌体为89微米。粘结水门汀后,冠的中位数增加到130微米,嵌体增加到92微米,粘结导致冠的边缘差异显著增加,但嵌体没有。粘结前后冠和嵌体的差异没有显著差异。

结论

本研究中发现的最大边缘差异在粘结前为50至265微米,粘结后为70至285微米,冠和嵌体的平均值之间没有显著差异。粘结水门汀导致冠基牙的边缘差异显著增加,但嵌体基牙没有。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验