• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Morphologic features of the acetabulum bone joint area].

作者信息

Gu Dongyun, Dai Kerong, Wang You, Hu Xin, Xi Juntong

机构信息

Shanghai 9th People's Hospital, Shanghai Second Medical University, Shanghai 200011.

出版信息

Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2003 Dec;20(4):618-21.

PMID:14716860
Abstract

The research on the morphology features of the acetabulum bone joint surface area would be helpful to establishing the acetabulum 3D model for the purpose of the biomechanical analysis of hip joint, and therefore might have its important clinical significance. However, in former studies, the acetabulum was simply considered as a semi sphere. In this study, based on the acetabulum 3D-point data acquired by the 3D laser surface scanner and the reverse engineering technology together with the optimal fit algorithm, two kinds of best-fit model were achieved by a sphere surface and a rotating elliptical surface respectively approaching to the acetabulum bone joint surface. Both fitting errors were then compared and analyzed. The results showed that the fitting error of the rotating elliptical surface was significantly less than that of the sphere surface (P < 0.001). The average radius of fitting sphere was 24.37 +/- 2.22 mm and the average long axis of fitting rotating elliptical surface was 26.02 +/- 2.76 mm while its short axis was 24.17 +/- 2.16 mm. These findings would be helpful to our new recognition of the acetabulum since they were results of the first quantitative analyses for the acetabulum bone surface and also might serve as an important reference base in its further studies and application.

摘要

相似文献

1
[Morphologic features of the acetabulum bone joint area].
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2003 Dec;20(4):618-21.
2
[A study on new computer-aided modeling method of hip joint].
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2004 Oct;21(5):828-31.
3
The shape of the acetabular cartilage surface: a geometric morphometric study using three-dimensional scanning.髋臼软骨表面的形态:一项使用三维扫描的几何形态测量学研究。
Med Eng Phys. 2008 Oct;30(8):1024-31. doi: 10.1016/j.medengphy.2007.12.013. Epub 2008 Feb 13.
4
[Morphological analysis of acetabulum bony curved surface].髋臼骨曲面的形态学分析
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2004 Oct;21(5):721-6.
5
Precision and accuracy of acetabular size measures in fragmentary hominin pelves obtained using sphere-fitting techniques.利用球体拟合技术获取的不完整原始人类骨盆髋臼尺寸的测量精度和准确性。
Am J Phys Anthropol. 2013 Apr;150(4):565-78. doi: 10.1002/ajpa.22228. Epub 2013 Feb 7.
6
Morphologic features of the acetabulum.
Arch Orthop Trauma Surg. 2005 Sep;125(7):453-61. doi: 10.1007/s00402-005-0020-6.
7
Multi-pelvis characterisation of articular cartilage geometry.关节软骨几何形状的多骨盆特征分析
Proc Inst Mech Eng H. 2013 Dec;227(12):1255-64. doi: 10.1177/0954411913500265. Epub 2013 Aug 21.
8
Morphological characteristics of the acetabulum.髋臼的形态学特征。
Coll Antropol. 2004;28 Suppl 2:221-6.
9
Localization of anatomical point landmarks in 3D medical images by fitting 3D parametric intensity models.通过拟合三维参数强度模型对三维医学图像中的解剖学点地标进行定位。
Med Image Anal. 2006 Feb;10(1):41-58. doi: 10.1016/j.media.2005.02.003.
10
Novel three-dimensional MRI technique for study of cartilaginous hip surfaces in Legg-Calvé-Perthes disease.用于研究Legg-Calvé-Perthes病中髋关节软骨表面的新型三维磁共振成像技术。
J Orthop Res. 2009 Aug;27(8):981-8. doi: 10.1002/jor.20909.

引用本文的文献

1
Acetabular morphology: implications for joint-preserving surgery.髋臼形态学:对保关节手术的影响。
Clin Orthop Relat Res. 2009 Mar;467(3):682-91. doi: 10.1007/s11999-008-0682-9. Epub 2009 Jan 8.