Fuhrmann Renée A, Wagner Andreas, Anders Jens O
Orthopaedic Department, University of Jena, Rudolf-Elle-Hospital, Klosterlausnitzerstr. 81, D-07607 Eisenberg, Germany.
Foot Ankle Clin. 2003 Dec;8(4):711-21, vi. doi: 10.1016/s1083-7515(03)00146-3.
Replacement of the first metatarsophalangeal (MTP) joint remains critical because of complex biomechanical conditions and implant fixation. After a 3-year follow-up, most patients who experienced an MTP joint replacement were extremely satisfied with the outcome. Plantar pressure distribution revealed a marked improvement. Nevertheless, recovery of MTP dorsiflexion was limited and joint stability worsened. Radiologically, one-third of the prostheses showed radiolucent lines as a sign of implant loosening. MTP replacement offers distinct advantages in the treatment of end-stage hallux rigidus, but requires further research on implant design and osseous fixation.
由于复杂的生物力学条件和植入物固定问题,第一跖趾关节置换术仍然具有挑战性。经过3年的随访,大多数接受跖趾关节置换术的患者对手术效果非常满意。足底压力分布显示出明显改善。然而,跖趾关节背屈的恢复有限,关节稳定性恶化。影像学检查显示,三分之一的假体出现透光线,这是植入物松动的迹象。跖趾关节置换术在终末期僵硬拇趾的治疗中具有明显优势,但需要对植入物设计和骨固定进行进一步研究。