Suppr超能文献

Intrapartum ultrasound estimation of total bladder volume.

作者信息

Gyampoh B, Crouch N, O'Brien P, O'Sullivan C, Cutner A

机构信息

Obstetric Hospital, University College London Hospitals, UK.

出版信息

BJOG. 2004 Feb;111(2):103-8. doi: 10.1046/j.1471-0528.2003.51107.x-i1.

Abstract

OBJECTIVE

To determine whether real-time ultrasound measurement of multiple linear dimensions of the bladder could be used to estimate total bladder volumes of women in labour.

AIM

To create a simple reproducible formula using ultrasound techniques to help estimate total bladder volumes of women in labour. This may prevent unnecessary catheterisation and conversely, avoid failure to catheterise when indicated, thereby reducing the complications associated with catheterisation and bladder overdistension.

DESIGN

Prospective, observational study of women in labour.

SETTING

Delivery Suite, Obstetric Hospital, University College London Hospitals.

POPULATION

Forty-nine women in labour recommended for catheterisation by their attending midwives.

METHOD

A real-time ultrasound scanner was used to measure bladder diameters in two planes: transverse width and height, and sagittal width and height. A Foley's catheter was inserted and the bladder drained into a graduated bowl under sterile conditions. These values and urine volumes were recorded and a formula for detecting bladder volumes above 300 mL was developed using linear regression methods and the Bland-Altman limits of agreement.

MAIN OUTCOME MEASURE

Sensitivity and specificity of derived formulae in predicting bladder volume from ultrasound measurements. Correctly predicted volumes greater than 300 mL.

RESULTS

Among the 49 women, 36 were nulliparous and 13 were multiparous. All had full-term pregnancies with cephalic presentation and were in active labour with cervical dilatations ranging from 3 to 10 cm. There were no previous caesarean sections among the multiparous women. Thirty-nine women had epidural analgesia. Indications for catheterisation included a palpable bladder per abdomen, or the interval from last urine voided. The catheterised volumes ranged from 30 to 720 mL with a median of 150 mL. The new equation (0.68 x h x d x w) had a sensitivity of 77% (95% CI 46-95%) and specificity of 86% (95% CI 71-95%) for detecting bladder volumes greater than 300 mL. In order to ensure that about 95% of women in need of catheterisation are detected, the above equation was improved using the Bland-Altman limits of agreement. The sensitivity of this final equation (1.74 x h x d x w) was 100% (95% CI 75-100%) and the specificity dropped to 36% (95% CI 21-54%).

CONCLUSION

It is possible to use real-time ultrasound in estimation of total bladder volumes of women in labour. The implications are that all of those normally selected as being in need of catheterisation could be detected, while about a quarter of those women would avoid unnecessary catheterisation.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验