• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

The effect of measurement conditions on MCG inverse solutions.

作者信息

Tan G A, Brauer F, Stroink G, Purcell C J

机构信息

Department of Physics, Dalhousie University, Halifax, Nova Scotia, Canada.

出版信息

IEEE Trans Biomed Eng. 1992 Sep;39(9):921-7. doi: 10.1109/10.256425.

DOI:10.1109/10.256425
PMID:1473820
Abstract

A magnetic inverse solution that uses a single current dipole in a homogeneous volume conductor with realistic torso shape was tested numerically to establish the effect of magnetic noise, number of measurement points, and torso size on the localization accuracy. Seven different sites of cardiological interest were selected as locations for the source dipole. The three components of the magnetic field were calculated as if measured by second order gradiometers, Gaussian noise was added, and Monte Carlo tests performed for inverse solutions using a single field component, or all three combined. It was found that for any of the single component solutions, and a signal-to-noise ratio of 100, 25 measuring points are sufficient for good accuracy; just 12 points are needed if all three components are used together. If, however, the torso size of the inverse solution is different from that of the field data by 10 or 20%, a larger error occurs, even for 56 measurement points and no noise. In this case, the field component orthogonal to the measurement grid, Bz, yields better results than the other two components, or even all three combined. We conclude that a multichannel system measuring the z component of the magnetic field in about 30 locations would be the best choice to locate a dipolar source, provided the torso of the field data is closely matched by the model used in the inverse solution. To this effect, scaling of the torso model can easily be included in the computation. Imaging techniques could be used to accommodate different torso shapes.

摘要

相似文献

1
The effect of measurement conditions on MCG inverse solutions.
IEEE Trans Biomed Eng. 1992 Sep;39(9):921-7. doi: 10.1109/10.256425.
2
Accuracy of a single equivalent moving dipole model in a realistic anatomic geometry torso model.
Comput Cardiol. 2000;27:439-42.
3
Applicability of the single equivalent moving dipole model in an infinite homogeneous medium to identify cardiac electrical sources: a computer simulation study in a realistic anatomic geometry torso model.单等效移动偶极子模型在无限均匀介质中识别心脏电源的适用性:在逼真的解剖几何躯干模型中的计算机模拟研究
IEEE Trans Biomed Eng. 2006 Dec;53(12 Pt 1):2436-44. doi: 10.1109/TBME.2006.880882.
4
Linear inverse solutions: simulations from a realistic head model in MEG.线性逆解:来自真实头部模型的脑磁图模拟
Brain Topogr. 2005 Winter;18(2):87-99. doi: 10.1007/s10548-005-0278-6. Epub 2005 Dec 5.
5
The effect of geometric and topologic differences in boundary element models on magnetocardiographic localization accuracy.边界元模型中的几何和拓扑差异对心磁图定位准确性的影响。
IEEE Trans Biomed Eng. 2000 Sep;47(9):1237-47. doi: 10.1109/10.867958.
6
A new method for regularization parameter determination in the inverse problem of electrocardiography.心电图逆问题中正则化参数确定的一种新方法。
IEEE Trans Biomed Eng. 1997 Jan;44(1):19-39. doi: 10.1109/10.553710.
7
Moving dipole inverse solutions using realistic torso models.
IEEE Trans Biomed Eng. 1991 Jan;38(1):82-4. doi: 10.1109/10.68213.
8
Relationship between dipole parameter estimation errors and measurement conditions in magnetoencephalography.脑磁图中偶极子参数估计误差与测量条件之间的关系。
IEEE Trans Biomed Eng. 1993 Sep;40(9):919-24. doi: 10.1109/10.245613.
9
The effect of torso geometry on magnetocardiographic isofield maps.躯干几何形状对心磁图等场图的影响。
Phys Med Biol. 1987 Jan;32(1):121-4. doi: 10.1088/0031-9155/32/1/018.
10
Solution of the inverse problem of magnetic induction tomography (MIT).磁感应断层成像(MIT)逆问题的解决方案。
Physiol Meas. 2005 Apr;26(2):S241-50. doi: 10.1088/0967-3334/26/2/023. Epub 2005 Mar 29.

引用本文的文献

1
The magnetocardiogram.心磁图
Biophys Rev (Melville). 2024 May 29;5(2):021305. doi: 10.1063/5.0201950. eCollection 2024 Jun.