Suppr超能文献

使用对比增强脂肪饱和三维稳态自由进动成像的磁共振门静脉造影。

Magnetic resonance portography using contrast-enhanced fat-saturated three-dimensional steady-state free precession imaging.

作者信息

Amano Yasuo, Takahama Katsuya, Nozaki Atsushi, Amano Maki, Kumazaki Tatsuo

机构信息

Department of Radiology, Nippon Medical School, Tokyo, Japan.

出版信息

J Magn Reson Imaging. 2004 Feb;19(2):238-44. doi: 10.1002/jmri.10442.

Abstract

PURPOSE

To assess the feasibility of contrast-enhanced fat-saturated three-dimensional steady-state free precession (FIESTA) imaging for contrast-enhanced magnetic resonance (MR) portography.

MATERIALS AND METHODS

Contrast-enhanced fat-saturated three-dimensional fast spoiled gradient-echo (SPGR) and FIESTA were performed as MR portography. In 10 cases, fat-saturated three-dimensional FIESTA was first performed and followed by fast SPGR, and the order of post-contrast imaging was reversed in the other 10 cases. Signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were estimated for portal and visceral veins on the source images. The visualization of portal vein was scored on three-dimensional MR portography. Portal venous system disorders were assessed using three-dimensional MR portography.

RESULTS

The SNRs, CNRs, and visual assessment of portal and visceral veins were significantly higher in contrast-enhanced fat-saturated three-dimensional FIESTA than contrast-enhanced fat-saturated three-dimensional fast SPGR (P < 0.05). The contrast-enhanced fat-saturated three-dimensional FIESTA provided high venous signals even at 8 minutes after gadolinium injection. The abnormalities of portal venous system were well visualized with MR portography using contrast-enhanced fat-saturated three-dimensional FIESTA.

CONCLUSION

Contrast-enhanced fat-saturated three-dimensional FIESTA was valuable for MR portography, with flexible time window and high vascular signals. This imaging may allow for other post-contrast imaging options before portography and release patients from consecutive breath-holds.

摘要

目的

评估对比增强脂肪饱和三维稳态自由进动(FIESTA)成像用于对比增强磁共振(MR)门静脉造影的可行性。

材料与方法

采用对比增强脂肪饱和三维快速扰相梯度回波(SPGR)和FIESTA进行MR门静脉造影。10例患者先进行脂肪饱和三维FIESTA成像,然后进行快速SPGR成像;另外10例患者对比剂注射后成像顺序相反。在源图像上评估门静脉和内脏静脉的信噪比(SNR)和对比噪声比(CNR)。对三维MR门静脉造影图像上门静脉的显示情况进行评分。利用三维MR门静脉造影评估门静脉系统疾病。

结果

对比增强脂肪饱和三维FIESTA成像时门静脉和内脏静脉的SNR、CNR及视觉评估均显著高于对比增强脂肪饱和三维快速SPGR成像(P<0.05)。对比增强脂肪饱和三维FIESTA成像即使在注射钆剂8分钟后仍能提供较高的静脉信号。采用对比增强脂肪饱和三维FIESTA成像的MR门静脉造影能很好地显示门静脉系统异常。

结论

对比增强脂肪饱和三维FIESTA成像对MR门静脉造影具有重要价值,具有灵活的时间窗和较高的血管信号。这种成像方式可能允许在门静脉造影前进行其他对比剂注射后的成像选择,并使患者无需连续屏气。