• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Clinical evaluation of a new fat removal filter during cardiac surgery.

作者信息

de Vries Adrianus J, Gu Y John, Douglas Yvonne L, Post Wendy J, Lip Harm, van Oeveren Willem

机构信息

Department of Anesthesiology, University Hospital Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.

出版信息

Eur J Cardiothorac Surg. 2004 Feb;25(2):261-6. doi: 10.1016/j.ejcts.2003.11.011.

DOI:10.1016/j.ejcts.2003.11.011
PMID:14747124
Abstract

OBJECTIVES

Fat microemboli are generated during cardiac surgery that are associated with post-operative organ injury. Recently, a fat removal filter has been developed, based on a polyester leukocyte depletion filter. However, the efficacy of such a filter in a clinical setting is unknown. In this study we tested the efficacy of this filter.

METHODS

Coronary artery bypass patients were randomly divided into two groups. Group I: filtration of cardiotomy suction blood during cardiopulmonary bypass with a fat removal filter (n=14). Group II: control patients without filtration (n=14). Filter efficacy was evaluated in group I using biochemical assays and thin layer chromatography of blood samples taken simultaneously before and after the filter. In addition, clinical and biochemical markers for organ injury were determined in both groups.

RESULTS

The fat filter removed triglycerides (0.9+/-0.08 vs. 0.63+/-0.08 mmol l(-1), P=0.004, paired t-test), leukocytes (4.3+/-0.8 x 10(9) vs. 2.3+/-0.6 x 10(9)l(-1), P=0.03), and platelets (116+/-26 x 10(9) vs. 75+/-21 x 10(9)l(-1), P=0.003) from the blood samples taken before and after the filter. Chromatography showed a significant reduction in free fatty acids, phospholipids and triglycerides. Clinically, leukocyte counts were similar, but platelet counts were higher (181+/-14 x 10(9) vs. 117+/-8.6 x 10(9)l(-1) control, P<0.001) in group I on the first postoperative day.

CONCLUSIONS

The fat filter removed 40% fat, leukocytes and platelets from cardiotomy suction blood during cardiac surgery. A larger scale study is necessary to determine clinical effects on organ damage.

摘要

相似文献

1
Clinical evaluation of a new fat removal filter during cardiac surgery.
Eur J Cardiothorac Surg. 2004 Feb;25(2):261-6. doi: 10.1016/j.ejcts.2003.11.011.
2
A prospective randomised comparison of cardiotomy suction and cell saver for recycling shed blood during cardiac surgery.
Eur J Cardiothorac Surg. 2003 Apr;23(4):633-6. doi: 10.1016/s1010-7940(02)00834-5.
3
Clinical efficacy and biocompatibility of three different leukocyte and fat removal filters during cardiac surgery.
Artif Organs. 2006 Jun;30(6):452-7. doi: 10.1111/j.1525-1594.2006.00241.x.
4
The embolic potential of liquid fat in pericardial suction blood, and its elimination.
Perfusion. 2003 Mar;18 Suppl 1:69-74. doi: 10.1191/0267659103pf630oa.
5
Leukocyte depleting filter attenuates myocardial injury during elective coronary artery bypass surgery.白细胞滤器可减轻择期冠状动脉搭桥手术期间的心肌损伤。
Scand Cardiovasc J. 2005 Dec;39(6):358-68. doi: 10.1080/14017430510035943.
6
Efficacy of a new oxygenator-integrated fat and leukocyte removal device.
Asian Cardiovasc Thorac Ann. 2010 Dec;18(6):546-50. doi: 10.1177/0218492310386516.
7
Fat contamination of pericardial suction blood and its influence on in vitro capillary-pore flow properties in patients undergoing routine coronary artery bypass grafting.
J Thorac Cardiovasc Surg. 2002 Aug;124(2):377-86. doi: 10.1067/mtc.2002.122303.
8
Leucocyte filtration during cardiopulmonary reperfusion in coronary artery bypass surgery.冠状动脉搭桥手术中心肺再灌注期间的白细胞过滤
Perfusion. 1999 Mar;14(2):107-17. doi: 10.1177/026765919901400204.
9
Elimination of fat microemboli during cardiopulmonary bypass.体外循环期间脂肪微栓子的清除。
Ann Thorac Surg. 2003 Feb;75(2):555-9; discussion 559. doi: 10.1016/s0003-4975(02)04540-x.
10
The effect of leucocyte-depleting arterial line filters on cerebral microemboli and neuropsychological outcome following coronary artery bypass surgery.白细胞去除动脉滤器对冠状动脉搭桥手术后脑微栓子及神经心理转归的影响。
Eur J Cardiothorac Surg. 2004 Feb;25(2):267-74. doi: 10.1016/j.ejcts.2003.11.007.

引用本文的文献

1
A Novel Macroscale Acoustic Device for Blood Filtration.一种用于血液过滤的新型宏观声学装置。
J Med Device. 2018 Mar;12(1):0110081-110087. doi: 10.1115/1.4038498. Epub 2018 Jan 19.
2
Cardiorespiratory effects of venous lipid micro embolization in an experimental model of mediastinal shed blood reinfusion.纵隔内失血回输实验模型中静脉脂质微栓塞的心肺效应
J Cardiothorac Surg. 2009 Sep 15;4:48. doi: 10.1186/1749-8090-4-48.
3
Evaluation of the Doppler technique for fat emboli detection in an experimental flow model.在实验血流模型中评估多普勒技术检测脂肪栓子的效果。
J Extra Corpor Technol. 2008 Sep;40(3):175-83.
4
Coronary artery surgery: cardiotomy suction or cell salvage?冠状动脉手术:心内吸引还是细胞回收?
J Cardiothorac Surg. 2007 Oct 25;2:46. doi: 10.1186/1749-8090-2-46.