We examined the period breath-alcohol values may be falsified owing to gasoline vapors with regard to the Alcomat currently used in routine tests. In a sober test person the breath-alcohol concentration was found to be 0.10/1000 24 min. after the inhalation of gasoline vapors, whereas the value measured after 28 min. was still 0.09/1000. 63 min. after the clothes had been moistened with gasoline, a breath-alcohol concentration of still 0.11/1000 could be identified immediately after inhalation.

摘要

我们针对目前常规测试中使用的酒精测试仪,研究了汽油蒸汽可能导致呼气酒精值被篡改的情况。在一名清醒的测试对象中,吸入汽油蒸汽24分钟后,呼气酒精浓度被发现为0.10/1000,而28分钟后测得的值仍为0.09/1000。在用汽油弄湿衣服63分钟后,吸入后立即测得呼气酒精浓度仍为0.11/1000。