Azevedo J E, Garcia-Fernandez M A, San Roman D, Torrecilla E, Esturau R, Hernandez J M, Echevarria T, Burgueno A, Delcan J L
Laboratório de Ecocardiografia, Hospital General Gregorio Maranon, Madrid.
Rev Port Cardiol. 1992 Sep;11(9):759-67.
Transesophageal (TEE) and Transthoracic (TTE) comparative echocardiographic analysis of patients with mitral valve prosthesis.
Prospective study.
In hospital and out patients with mitral prosthesis in a follow-up study by the Cardiology Department and referred to the echocardiographic laboratory of Gregorio Marañon General Hospital, Madrid.
We studied 90 consecutive patients with mitral prosthesis diagnosis.
Comparative and prospective echocardiographic study of transthoracic and transesophageal techniques in mitral prosthesis pathology.
TTE diagnosed 18% of dysfunctioning mitral prosthesis patients compared to 56% of cases identified by TEE. TTE observed 1% of mitral prosthesis vegetation compared to 8.8% by TEE. TEE diagnosed left atrial thrombosis in 2.2% and TEE in 10%. Left atrial spontaneous dynamic contrast was identified exclusively by TEE in 55% of all cases. Paravalvular mitral prosthesis leak was correctly identified exclusively by TEE in 20% of cases.
TEE has a greater diagnostic capacity compared to TTE in mitral prosthesis patients. This technique can give a greater security in evaluating mitral prosthesis thrombi, vegetations and leak, establishing a more precise diagnosis of mitral prosthesis dysfunction. The authors concluded that TEE is the technique of choice in noninvasive evaluation of patients admitted with the suspicion of mitral prosthesis dysfunction.
对二尖瓣人工瓣膜置换患者进行经食管(TEE)和经胸(TTE)超声心动图对比分析。
前瞻性研究。
在马德里格雷戈里奥·马拉尼翁综合医院心脏病科进行的一项随访研究中,对住院和门诊的二尖瓣人工瓣膜置换患者进行研究,并将其转诊至超声心动图实验室。
我们对90例连续诊断为二尖瓣人工瓣膜置换的患者进行了研究。
对二尖瓣人工瓣膜病变患者进行经胸和经食管技术的对比性前瞻性超声心动图研究。
TTE诊断出18%的二尖瓣人工瓣膜功能障碍患者,而TEE诊断出56%的此类患者。TTE观察到1%的二尖瓣人工瓣膜赘生物,而TEE观察到8.8%。TEE诊断出2.2%的左心房血栓,TTE诊断出10%。在所有病例中,55%的左心房自发显影仅由TEE发现。20%的瓣周二尖瓣人工瓣膜漏仅由TEE正确识别。
在二尖瓣人工瓣膜置换患者中,TEE比TTE具有更强的诊断能力。该技术在评估二尖瓣人工瓣膜血栓、赘生物和瓣膜漏方面能提供更高的安全性,对二尖瓣人工瓣膜功能障碍做出更精确的诊断。作者得出结论,对于怀疑有二尖瓣人工瓣膜功能障碍的患者,TEE是无创评估的首选技术。