Pedal I, Graf W
Institut für Rechtsmedizin, Universität Heidelberg.
Arch Kriminol. 1992 Nov-Dec;190(5-6):156-62.
A 55-year-old man was found unconscious with ventricular fibrillations at his working place near a power press. CPR was successful. After three weeks of intensive care the patient died of ischemic brain damage. The first suspected diagnosis of myocardial infarction was revised when typical current marks were detected on both palms. At the working place the top of a lubricating grease container was found to be energized due to a technical damage: There is a round, multiple-pole plug mounted upon the container top the proper orientation of which is coded by a set of five plastic nipples. All the nipples had been abraded by longlasting mechanical stress, so that the plug could be connected in a variety of possible orientations. In actual fact, the incorrect orientation caused a voltage of up to 240 V to the container top.