Suppr超能文献

数字减影涎腺造影术:技术、优势及107例病例的结果

Digital subtraction sialography: technique, advantages and results in 107 cases.

作者信息

Ilgit E T, Cizmeli M O, Işik S, Araç M, Altin M, Köker E

机构信息

Department of Radiology, School of Medicine, Gazi University, Ankara, Turkey.

出版信息

Eur J Radiol. 1992 Oct;15(3):244-7. doi: 10.1016/0720-048x(92)90116-q.

Abstract

Sialographic examinations with the digital subtraction technique were performed in 107 salivary glands (90 parotid and 17 submandibular) of 99 patients. Diagnostic and technical advantages of the digital imaging and subtraction for sialography were investigated. Superior quality enabled detailed imaging of the entire ductal system. Reduced radiation exposure, short examination time and almost painless examinations with good patient tolerance proved to be the major advantages of digital subtraction sialography as a diagnostic tool.

摘要

对99例患者的107个唾液腺(90个腮腺和17个下颌下腺)进行了数字减影技术唾液造影检查。研究了数字成像和减影技术在唾液造影中的诊断和技术优势。高质量成像能够对整个导管系统进行详细成像。减少辐射暴露、缩短检查时间以及几乎无痛且患者耐受性良好,这些被证明是数字减影唾液造影作为一种诊断工具的主要优势。