• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Possible sources of discrepancy between sphygmomanometer cuff pressure and blood pressure quantified in a collapsible-tube analogue.

作者信息

Bertram C D, Butcher K S

机构信息

Centre for Biomedical Engineering, University of New South Wales, Kensington, Sydney, Australia.

出版信息

J Biomech Eng. 1992 Feb;114(1):68-77. doi: 10.1115/1.2895452.

DOI:10.1115/1.2895452
PMID:1491589
Abstract

This paper examines the assumption that the audible events detected as Korotkov sounds in sphygmomanometry occur when blood pressure equals arm-cuff pressure. Several effects that contribute to discrepancy between these pressures are quantified using an idealised arm-and-cuff system consisting of a thick-walled collapsible tube subject to external compression along a central part of its length. The effects studied are (1) transverse pressure difference, resulting from tissues sustaining a part of the external compression through (a) circumferential bending stiffness and (b) longitudinal curvature of the tensed localised neck at the site of initial collapse, (2) longitudinal pressure difference between upstream pressure and pressure at the collapse point due to both (a) viscous and (b) inertial pressure drop. These effects are found to compensate partially for each other; the pressure within the vessel at the collapse point is less than the cuff pressure, but is also less than the blood pressure at the upstream end of the cuff. All four of the contributing terms increase proportionally to the flow-rate raised to a power greater than one, except the viscous pressure drop. Owing to a progressive shortening of the collapsed neck as flow-rate increases, the viscous term is almost independent of the flow-rate. The overall discrepancy displays less flow-rate dependency and is smaller than some of the terms which contribute to it. This means that considerable accuracy is needed if measurements of the effects are to be used to correct the raw data on cuff pressure at the time of Korotkov sound emission so as to obtain an improved estimate of the blood pressure.

摘要

相似文献

1
Possible sources of discrepancy between sphygmomanometer cuff pressure and blood pressure quantified in a collapsible-tube analogue.
J Biomech Eng. 1992 Feb;114(1):68-77. doi: 10.1115/1.2895452.
2
Blood flow in a brachial artery compressed externally by a pneumatic cuff.肱动脉中的血流受到外部气动袖带的压迫。
J Biomech Eng. 1992 Feb;114(1):78-83. doi: 10.1115/1.2895453.
3
Numerical simulation of noninvasive blood pressure measurement.无创血压测量的数值模拟
J Biomech Eng. 2006 Oct;128(5):680-7. doi: 10.1115/1.2241592.
4
Optimizing cuff width for noninvasive measurement of blood pressure.优化用于无创血压测量的袖带宽度。
Blood Press Monit. 2000 Jun;5(3):153-8. doi: 10.1097/00126097-200006000-00002.
5
Variation of the Korotkoff Stethoscope Sounds During Blood Pressure Measurement: Analysis Using a Convolutional Neural Network.血压测量过程中柯氏音的变化:卷积神经网络分析。
IEEE J Biomed Health Inform. 2017 Nov;21(6):1593-1598. doi: 10.1109/JBHI.2017.2703115.
6
Portable blood pressure measurements using the Korotkov sound technique--a study of measurement accuracy.使用柯氏音技术进行便携式血压测量——测量准确性研究
Biomed Sci Instrum. 1979;15:101-4.
7
Comparisons of blood pressure measurements by auscultation and Physiometrics Infrasonde recording techniques.通过听诊法和物理测量次声记录技术进行血压测量的比较。
Hypertension. 1980 Jul-Aug;2(4 Pt 2):I8-17. doi: 10.1161/01.hyp.2.4_pt_2.i8.
8
Indirect blood pressure measurements: a matter of interpretation.间接血压测量:一个解释的问题。
Angiology. 1979 Oct;30(10):683-95. doi: 10.1177/000331977903001005.
9
The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure--part ii.间接测量血压时袖带压力最大振荡点的意义——第二部分。
J Biomech Eng. 1980 Feb;102(1):28-33. doi: 10.1115/1.3138195.
10
Measurement of arterial closing pressure.
Physiol Meas. 1993 Feb;14(1):7-12. doi: 10.1088/0967-3334/14/1/002.

引用本文的文献

1
Hemodynamics.血液动力学
Compr Physiol. 2016 Mar 15;6(2):975-1003. doi: 10.1002/cphy.c150038.