Swanepoel Dewet, Schmulian Dunay, Hugo René
Department of Communication Pathology, University of Pretoria, Pretoria, South Africa.
Acta Otolaryngol. 2004 Jan;124(1):62-8. doi: 10.1080/00016480310015902.
To determine the clinical usefulness of the dichotic multiple-frequency (MF) auditory steady-state response (ASSR) technique for estimating normal hearing compared to a 0.5-kHz tone burst and broadband click auditory brainstem response (ABR) protocol in a sample of adults.
A comparative experimental research design was selected in order to compare estimations of normal hearing obtained with the dichotic ASSR technique at 0.5, 1, 2 and 4 kHz with a 0.5-kHz tone burst and broadband click ABR protocol. The recording times required for each procedure were also compared. Normal-hearing subjects (n = 28) were selected according to immittance values within normal limits and pure-tone behavioural thresholds of < 25 dB HL across frequencies.
The dichotic MF ASSR estimated normal hearing to be, on average, 30-34 dB HL across the range 0.5-4 kHz. The mean estimate of normal hearing for 0.5 kHz using tone burst ABRs was 30 dB nHL and the mean click ABR threshold was 16 dB nHL, i.e. 14-18 dB better than the ASSR thresholds. The dichotic MFASSR technique recorded 8 thresholds (4 in each ear) in a mean time of 23 min. The ABR protocol recorded 4 thresholds (2 in each ear) in a mean time of 25 min.
Both the dichotic MF ASSR and ABR protocols provided a time-efficient estimation of normal hearing. There was no significant difference between the tone burst ABR and MF ASSR techniques in terms of estimation of normal hearing at 0.5 kHz. The dichotic MF ASSR technique proved more time-efficient by determining more thresholds in a shorter time compared to the ABR protocol.
在一组成年人样本中,将双耳多频(MF)听觉稳态反应(ASSR)技术与0.5kHz短纯音和宽带短声听觉脑干反应(ABR)方案进行比较,以确定其在评估正常听力方面的临床实用性。
选择一项对比实验研究设计,以便将双耳ASSR技术在0.5、1、2和4kHz时获得的正常听力评估结果与0.5kHz短纯音和宽带短声ABR方案进行比较。还比较了每个程序所需的记录时间。根据声导抗值在正常范围内且各频率纯音行为阈值<25dB HL的标准,选择听力正常的受试者(n = 28)。
双耳MF ASSR估计0.5 - 4kHz范围内的正常听力平均为30 - 34dB HL。使用短纯音ABR评估0.5kHz正常听力的平均估计值为30dB nHL,短声ABR的平均阈值为16dB nHL,即比ASSR阈值好14 - 18dB。双耳MFASSR技术平均用时23分钟记录8个阈值(每耳4个)。ABR方案平均用时25分钟记录4个阈值(每耳2个)。
双耳MF ASSR和ABR方案都能高效地评估正常听力。在0.5kHz正常听力评估方面,短纯音ABR和MF ASSR技术之间没有显著差异。与ABR方案相比,双耳MF ASSR技术在更短时间内确定更多阈值,证明其效率更高。