Rheological behaviour of filamentous sludges originated from activated sludge reactors was studied. Filamentous bulking was detected via a hysteresis loop developed from rheograms resulting from increasing-decreasing shear rates. The rheological parameter reduced hysteresis area (rHa), corresponding to the loop area developed by rheograms was used to quantify filamentous bulking. Application to the evolution of several bulkings was carried out and it was shown that filaments proliferation and disappearance were correlated with, respectively, the increasing and decreasing of the value of the parameter rHa. In parallel with rheological measurement, parameters used for the study of sludge quality, such as sludge volume index (SVI) and settling initial flow (F0), were determined for comparison during the evolution of several bulkings. It was shown that rHa was more sensitive to the appearance of filamentous bulking than SVI and F0, therefore it was concluded that detection of filamentous bulking can be shown from rHa.
研究了源自活性污泥反应器的丝状污泥的流变行为。通过由剪切速率增加-降低产生的流变图形成的滞后环检测丝状膨胀。对应于流变图形成的环面积的流变参数减小滞后面积(rHa)用于量化丝状膨胀。对几种膨胀的演变进行了应用研究,结果表明丝状菌的增殖和消失分别与参数rHa值的增加和降低相关。在进行流变测量的同时,确定了用于研究污泥质量的参数,如污泥体积指数(SVI)和沉降初始流量(F0),以便在几种膨胀的演变过程中进行比较。结果表明,rHa对丝状膨胀的出现比SVI和F0更敏感,因此得出结论,可通过rHa检测丝状膨胀。