Suppr超能文献

传统快速自旋回波、单次激发二维和三维半傅里叶快速采集弛豫增强序列用于女性盆腔T2加权成像的比较。

Comparison of conventional fast spin echo, single-shot two-dimensional and three-dimensional half-fourier RARE for T2-weighted female pelvic imaging.

作者信息

Sugimura Hiroshi, Yamaguchi Kenichiro, Furukoji Eiji, Tamura Shozo, Sakae Tatefumi, Koga Haruyuki, Machida Yoshio, Kitane Shinichi

机构信息

Department of Radiology, Miyazaki Medical College, University of Miyazaki, Kiyotake, Miyazaki, Japan.

出版信息

J Magn Reson Imaging. 2004 Mar;19(3):349-55. doi: 10.1002/jmri.20010.

Abstract

PURPOSE

To evaluate the usefulness of the three-dimensional half-Fourier RARE sequence in comparison with single-shot two-dimensional half-Fourier RARE and conventional fast spin echo (FSE) for female pelvic imaging.

MATERIALS AND METHODS

Imaging with all sequences was performed in 146 patients with 166 focal lesions on a 1.5-T system. The images were compared on the basis of quality, lesion conspicuity, and lesion to the uterus contrast-to-noise ratio (CNR).

RESULTS

The sharpness of intrapelvic organs on the three-dimensional half-Fourier RARE sequence was better than that on two-dimensional half-Fourier RARE and worse than that on FSE. Motion-related artifacts for three-dimensional half-Fourier RARE were more frequent than those for two-dimensional half-Fourier RARE. There was no statistical difference between the three-dimensional half-Fourier RARE sequence and FSE in regard to lesion conspicuity and overall image quality. The CNR of leiomyoma to myometrium and cervical cancer to cervical stroma was the highest with three-dimensional half-Fourier RARE (P< 0.05).

CONCLUSION

The three-dimensional half-Fourier RARE sequence generates images with higher contrast and better image resolution than two-dimensional-RARE. The three-dimensional data set provided images that can be observed in any orientation without acquiring an additional scan by using the multiplanar reconstruction (MPR) method.

摘要

目的

评估三维半傅里叶快速自旋回波序列(three-dimensional half-Fourier RARE sequence)与单次激发二维半傅里叶快速自旋回波序列及传统快速自旋回波序列(FSE)相比,在女性盆腔成像中的应用价值。

材料与方法

在1.5-T系统上,对146例患有166个局灶性病变的患者进行了所有序列的成像。基于图像质量、病变清晰度以及病变与子宫的对比噪声比(CNR)对图像进行比较。

结果

三维半傅里叶快速自旋回波序列上盆腔内器官的清晰度优于二维半傅里叶快速自旋回波序列,但不如FSE。三维半傅里叶快速自旋回波序列的运动相关伪影比二维半傅里叶快速自旋回波序列更常见。在病变清晰度和整体图像质量方面,三维半傅里叶快速自旋回波序列与FSE之间无统计学差异。三维半傅里叶快速自旋回波序列下子宫肌瘤与子宫肌层以及宫颈癌与宫颈基质的CNR最高(P<0.05)。

结论

与二维快速自旋回波序列相比,三维半傅里叶快速自旋回波序列生成的图像具有更高的对比度和更好的图像分辨率。三维数据集提供的图像可以通过多平面重建(MPR)方法在任何方向观察,而无需额外扫描。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验