Lusuardi M, Capelli A, Donner C F, Capelli O, Velluti G
Clinica del Lavoro Foundation, Medical Center of Rehabilitation, Veruno, Italy.
Eur Respir J. 1992 Jul;5(7):798-803.
To evaluate the possibility of quantifying alveolar dust burden in conditions of exposure to silica, four groups of subjects were submitted to bronchoalveolar lavage (BAL): 10 healthy control subjects and 39 patients affected by diffuse interstitial lung disease (DILD) never exposed to dust, 23 silicotic patients and 12 chronic bronchitis patients with a history of occupational exposure to silica dust. Five to ten million BAL recovered cells were analysed with an energy-dispersive X-ray microanalysis (EDXA) system to determine the silicon content, expressed in a semi-quantitative way as silicon to sulphur (Si/S) ratio. The results were independent of smoking habit. The Si/S median values (interquartile range in brackets) for the four groups were 0.53 (0.5-0.65), 0.60 (0.41-0.8), 1.23 (1.06-1.39), 1.31 (1.11-1.97), respectively. Silicotics and simply exposed individuals did not show a significant discrepancy, but they were both significantly different in comparison with normal and DILD patients without history of exposure (p less than 0.001). 14.3% false negative cases were found, and 4.1% false positive cases (none among normal subjects). We did not see any significant relationships between the amount of silicon and the duration of exposure or the degree of chest X-ray involvement. A study of cytocentrifuge slides from the same subjects by polarizing light microscopy revealed a lower sensitivity (34% false negative cases).(ABSTRACT TRUNCATED AT 250 WORDS)
为评估在接触二氧化硅的情况下量化肺泡粉尘负荷的可能性,四组受试者接受了支气管肺泡灌洗(BAL):10名健康对照受试者、39名从未接触过粉尘的弥漫性间质性肺病(DILD)患者、23名矽肺患者和12名有职业性接触二氧化硅粉尘病史的慢性支气管炎患者。使用能量色散X射线微分析(EDXA)系统分析500万至1000万个回收的BAL细胞,以确定硅含量,以硅与硫(Si/S)比值的半定量方式表示。结果与吸烟习惯无关。四组的Si/S中位数(括号内为四分位间距)分别为0.53(0.5 - 0.65)、0.60(0.41 - 0.8)、1.23(1.06 - 1.39)、1.31(1.11 - 1.97)。矽肺患者和仅接触过粉尘的个体之间没有显著差异,但与无接触史的正常人和DILD患者相比,他们均有显著差异(p小于0.001)。发现14.3%的假阴性病例和4.1%的假阳性病例(正常受试者中无假阳性病例)。我们未发现硅含量与接触时间或胸部X线受累程度之间存在任何显著关系。通过偏振光显微镜对同一受试者的细胞离心涂片进行研究发现敏感性较低(34%的假阴性病例)。(摘要截选至250字)