Suppr超能文献

一种化学消毒剂对牙科石膏物理性能的影响。

Effects of a chemical disinfectant on the physical properties of dental stones.

作者信息

Hall B Daniel, Muñoz-Viveros Carlos A, Naylor W Patrick, Sy Jenny

机构信息

Department of Restorative Dentistry, Loma Linda University School of Dentistry, California 92350, USA.

出版信息

Int J Prosthodont. 2004 Jan-Feb;17(1):65-71.

Abstract

PURPOSE

This study compared the effects of an antimicrobial agent (Asepto-Sol) on the physical properties of types III, IV, and V gypsum casts made from two types of impression materials.

MATERIALS AND METHODS

Selected physical properties of five gypsum-based dental stones (Prima-Rock, Ortho Stone, New Fujirock, Die-Keen, Microstone) and two resin-based dental stones (Resin-Rock, Instone) were evaluated using an addition silicone impression material (Reprosil) and an irreversible hydrocolloid (Jeltrate Plus). In group 1, Asepto-Sol solution replaced water as the gauging liquid for the seven dental stones. The mixed gypsum was poured directly onto impressions of two master dies using two impression materials. In group 2, impressions made with both impression materials were sprayed with the Asepto-Sol solution, left for 10 minutes, rinsed for 30 seconds with tap water, and poured with each dental stone mixed with deionized water. In group 3 (control), the gypsums were mixed with deionized water and the mixed stone was poured directly into impressions, with no exposure to Asepto-Sol. The physical properties evaluated for the gypsum specimens were linear dimensional change, detail reproduction, Knoop hardness, and transverse strength.

RESULTS

The linear dimensional stability, detail reproduction, and transverse strength tests were relatively unaffected by the use of Asepto-Sol, with few exceptions. Detail reproduction appeared to be least affected by Asepto-Sol, and changes in Knoop hardness were noted but results differed among the seven dental stones. However, New Fujirock was not ideally matched with Jeltrate Plus, and no stone specimens could be produced.

CONCLUSION

Whether mixed with the gypsum powder or sprayed on impressions, Asepto-Sol solution did not adversely affect the physical properties of the dental stones tested.

摘要

目的

本研究比较了一种抗菌剂(Asepto - Sol)对由两种印模材料制成的III型、IV型和V型石膏模型物理性能的影响。

材料与方法

使用加成型硅橡胶印模材料(Reprosil)和不可逆水胶体(Jeltrate Plus)对五种石膏基牙科石膏(Prima - Rock、Ortho Stone、New Fujirock、Die - Keen、Microstone)和两种树脂基牙科石膏(Resin - Rock、Instone)的选定物理性能进行评估。在第1组中,Asepto - Sol溶液替代水作为七种牙科石膏的调和液体。将混合好的石膏直接灌注到使用两种印模材料制作的两个主模型的印模上。在第2组中,用两种印模材料制作的印模均喷洒Asepto - Sol溶液,放置10分钟,用自来水冲洗30秒,然后用与去离子水混合的每种牙科石膏灌注。在第3组(对照组)中,石膏与去离子水混合,将混合好的石膏直接灌注到印模中,不接触Asepto - Sol。评估石膏标本的物理性能包括线性尺寸变化、细节再现、努氏硬度和横向强度。

结果

线性尺寸稳定性、细节再现和横向强度测试相对不受Asepto - Sol使用的影响,仅有少数例外。细节再现似乎受Asepto - Sol的影响最小,观察到努氏硬度有变化,但七种牙科石膏的结果有所不同。然而,New Fujirock与Jeltrate Plus的匹配不理想,无法制作出石膏标本。

结论

无论是与石膏粉混合还是喷洒在印模上,Asepto - Sol溶液均未对所测试牙科石膏的物理性能产生不利影响。