Suppr超能文献

一种乙烯基聚醚硅橡胶印模材料在长时间储存过程中的尺寸稳定性的体外研究。

An in vitro study on the dimensional stability of a vinyl polyether silicone impression material over a prolonged storage period.

机构信息

Department of Dentistry, Faculty of Engineering, University of Alberta, Edmonton, Alberta, Canada.

出版信息

J Prosthet Dent. 2013 Mar;109(3):172-8. doi: 10.1016/S0022-3913(13)60038-4.

Abstract

STATEMENT OF PROBLEM

A new elastomeric impression material, a vinyl polyether silicone, has been commercially introduced. Its dimensional stability at different pouring times has not been reported.

PURPOSE

The purpose of this study was to evaluate the dimensional stability of vinyl polyether silicone (VPES) impressions as a function of delayed-pouring time for up to 2 weeks after performing a recommended clinical disinfection procedure.

MATERIAL AND METHODS

The 3 medium-body impression materials tested were EXA'lence 370, Imprint 3, and Impregum Penta soft. Impressions of a cylindrical metal model, which served as a control, were made and poured in a Type V stone after being disinfected in 2.5% buffered glutaraldehyde solution. Die diameter and anteroposterior and cross-arch measurements on each cast were made and compared to direct measurements of the control with a digital micrometer. The linear dimensional changes were compared and analyzed by using the Mann-Whitney U test (α=.05).

RESULTS

Considering the absolute values for the mean percentage dimensional change, VPES cast measurements were below 1.0% (P<.001), with the majority being minimal (≤0.34%) at all pour times. Measurements of the casts were larger than those of the control in all but one specimen. The percentage dimensional changes of the individual die diameters were higher than those of the anteroposterior and cross-arch linear measurements. Casts produced from VPES impressions had similar dimensional changes to those of VPS at 1 week of storage and similar changes to those of PE at 2 weeks of storage. The behavior of VPES impressions varied from being the most accurate at immediate-pour to gradually exhibiting higher dimensional changes as time progressed.

CONCLUSIONS

Casts produced from a disinfected regular set VPES (EXA'lence 370 monophase) demonstrated excellent dimensional stability at different pour times and were comparable to the tested VPS and PE impression materials.

摘要

问题陈述

一种新型弹性体印模材料,乙烯基聚醚硅酮,已商业化推出。其在不同浇注时间的尺寸稳定性尚未报道。

目的

本研究旨在评估乙烯基聚醚硅酮(VPES)印模在进行推荐的临床消毒程序后长达 2 周的不同浇注时间的尺寸稳定性。

材料和方法

测试的 3 种中体印模材料为 EXA'lence 370、Imprint 3 和 Impregum Penta 软。对圆柱形金属模型进行印模,并用 2.5%缓冲戊二醛溶液消毒后,在 V 型石中浇注。对每个铸件的模具直径以及前后和跨弓测量,并与数字千分尺直接测量的对照物进行比较。使用曼-惠特尼 U 检验(α=.05)比较和分析线性尺寸变化。

结果

考虑到平均尺寸变化百分比的绝对值,VPES 铸件测量值低于 1.0%(P<.001),大多数(≤0.34%)在所有浇注时间都很小。除一个样本外,铸件的测量值均大于对照物。各个模具直径的尺寸变化百分比高于前后和跨弓线性测量的尺寸变化百分比。VPES 印模在 1 周储存时的尺寸变化与 VPS 相似,在 2 周储存时的尺寸变化与 PE 相似。VPES 印模的行为从即时浇注的最准确逐渐变为随着时间的推移逐渐表现出更高的尺寸变化。

结论

从已消毒的常规 VPES(EXA'lence 370 单阶段)印模中制作的铸件在不同浇注时间表现出出色的尺寸稳定性,与测试的 VPS 和 PE 印模材料相当。