It is well documented that children, particularly between the ages of about 2 and 6 years, exhibit a high prevalence and incidence of otitis media. Distortion product otoacoustic emissions (DPOAEs) offer great potential for clinical testing of cochlear function in children. The aim of the present study was to determine the influence of middle ear effusion and physical properties of the effusion on the recording of DPOAE.
Nineteen children (38 ears) undergoing myringotomy and/or tympanostomy tube insertion for secretory otitis media were studied. Pre-operative and post-operative first day DPOAE signal to noise ratios were compared. The results were analyzed by paired samples test and ANOVA statistical methods.
We were found significant differences between pre-operative and post-operative first day DPOAE signal to noise at 1, 1.5, 2 and 4kHz. In addition, comparison of the pre-operative DPOAE signal to noise ratio and per-operative middle ear findings are shown significant differences between glue (thick mucous) and the other three groups (mucous, serous and no-effusion groups) at 2 and 4kHz, and between glue and no effusion group at 8kHz. Also post-operative DPOAE signal to noise ratio in relation to per-operative middle ear findings were significantly different at 2, 4 and 8kHz. The most increase of emissions at the post-operative first day was seen in ears with glue effusion at 1 and 2kHz.
Otitis media with effusion can be monitored by DPOAE measurement pre-operatively and post-operatively. In the pre-operative evaluation, glue effusion may cause a reduction in the emissions at 2, 4 and 8kHz more than the other kind effusions.
有充分文献记载,儿童,尤其是年龄在约2至6岁之间的儿童,中耳炎的患病率和发病率很高。畸变产物耳声发射(DPOAE)在儿童耳蜗功能的临床测试中具有很大潜力。本研究的目的是确定中耳积液及积液的物理特性对DPOAE记录的影响。
对19名因分泌性中耳炎接受鼓膜切开术和/或鼓膜置管术的儿童(38耳)进行了研究。比较术前和术后第一天的DPOAE信噪比。结果采用配对样本检验和方差分析统计方法进行分析。
我们发现术前和术后第一天在1、1.5、2和4kHz处的DPOAE信噪比存在显著差异。此外,术前DPOAE信噪比与术中中耳检查结果的比较显示,在2和4kHz时,胶状(浓稠黏液)积液组与其他三组(黏液、浆液和无积液组)之间存在显著差异,在8kHz时,胶状积液组与无积液组之间存在显著差异。术后DPOAE信噪比与术中中耳检查结果在2、4和8kHz时也存在显著差异。术后第一天,1和2kHz处胶状积液耳的耳声发射增加最多。
中耳积液性中耳炎可通过术前和术后的DPOAE测量进行监测。在术前评估中,胶状积液可能比其他类型的积液更易导致2、4和8kHz处的耳声发射降低。