Grafton脱矿骨基质凝胶与自体骨在腰椎后外侧融合术中的两年融合率等效性:一项在同一患者中采用并排比较的前瞻性对照试验。

Two-year fusion rate equivalency between Grafton DBM gel and autograft in posterolateral spine fusion: a prospective controlled trial employing a side-by-side comparison in the same patient.

作者信息

Cammisa Frank P, Lowery Gary, Garfin Steven R, Geisler Fred H, Klara Peter M, McGuire Robert A, Sassard Walter R, Stubbs Harrison, Block Jon E

机构信息

Hospital for Special Surgery, New York, New York, USA.

出版信息

Spine (Phila Pa 1976). 2004 Mar 15;29(6):660-6. doi: 10.1097/01.brs.0000116588.17129.b9.

Abstract

STUDY DESIGN

Multicenter, prospective equivalency trial with each patient serving as his/her own control.

OBJECTIVES

To compare the effectiveness of a Grafton DBM gel composite with iliac crest autograft in posterolateral spine fusion.

SUMMARY OF BACKGROUND DATA

While autograft remains the preferred graft material to facilitate spine fusion, the supply is limited and harvesting produces undesirable clinical consequences.

METHODS

A total of 120 patients underwent posterolateral spine fusion with pedicle screw fixation and bone grafting. Iliac crest autograft was implanted on one side of the spine and a Grafton DBM/autograft composite was implanted on the contralateral side in the same patient. An independent, blinded reviewer evaluated anteroposterior and lateral flexion-extension radiographs. The fusion mass lateral to the instrumentation on each side was judged fused or not, and the mineralization of the graft was rated absent, mild, moderate, or extensive. The degree of correspondence in outcomes between sides was estimated by computing the percentage agreement and kappa statistic.

RESULTS

Nearly 70% of patients (81 of 120) provided complete 24-month radiographic studies. The bone graft mass was fused in 42 cases (52%) on the Grafton DBMside and in 44 cases (54%) on the autograft side. The overall percentage agreement for fusion status between sides was approximately 75% (61 of 81), indicating moderately strong statistical correspondence (kappa = 0.51, P < 0.0001). Bone mineralization ratings also were similar between treated sides. Perfect agreement was realized in almost 60% of patients (48 of 81) with moderate statistical correspondence (weighted kappa = 0.54, P < 0.0001).

CONCLUSIONS

Grafton DBM can extend a smaller quantity of autograft than is normally required to achieve a solid spinal arthrodesis. Consequently, a reduced amount of harvested autograft may be required, potentially diminishing the risk and severity of donor site complications.

摘要

研究设计

多中心前瞻性等效性试验,每位患者自身作为对照。

目的

比较Grafton脱钙骨基质凝胶复合材料与髂嵴自体骨在后外侧脊柱融合术中的有效性。

背景资料总结

虽然自体骨仍然是促进脊柱融合的首选移植材料,但供应有限且获取会产生不良临床后果。

方法

共有120例患者接受了椎弓根螺钉固定和植骨的后外侧脊柱融合术。在同一患者的脊柱一侧植入髂嵴自体骨,在对侧植入Grafton脱钙骨基质/自体骨复合材料。一名独立的、不知情的评估者对前后位和侧位屈伸位X线片进行评估。判断器械两侧的融合块是否融合,并将移植骨的矿化程度评为无、轻度、中度或广泛。通过计算一致性百分比和kappa统计量来估计两侧结果的对应程度。

结果

近70%的患者(120例中的81例)提供了完整的24个月影像学研究。Grafton脱钙骨基质侧有42例(52%)的植骨块融合,自体骨侧有44例(54%)融合。两侧融合状态的总体一致性百分比约为75%(81例中的61例),表明统计学对应性较强(kappa = 0.51,P < 0.0001)。治疗侧的骨矿化分级也相似。近60%的患者(81例中的48例)实现了完全一致,统计学对应性中等(加权kappa = 0.54,P < 0.0001)。

结论

Grafton脱钙骨基质可以用比实现稳固脊柱融合通常所需量更少的自体骨。因此,可能需要减少自体骨的获取量,从而潜在地降低供区并发症的风险和严重程度。