Suppr超能文献

Stabilization of anterior cervical spine with bioabsorbable polymer in one- and two-level fusions.

作者信息

Park Min S, Aryan Henry E, Ozgur Burak M, Jandial Rahul, Taylor William R

机构信息

Division of Neurological Surgery, University of California, San Diego Medical Center, San Diego, California 92103-8893, USA.

出版信息

Neurosurgery. 2004 Mar;54(3):631-5; discussion 635. doi: 10.1227/01.neu.0000108942.07872.2a.

Abstract

OBJECTIVE

We present our experience using a bioabsorbable polymer in the surgical management of one- and two-level degenerative disc disease of the cervical spine with anterior cervical discectomy and fusion. Twenty-six patients were treated at the University of California, San Diego Medical Center or the Veterans Affairs Medical Center in San Diego, CA. All cases were performed under the direction of a single neurosurgeon (WRT).

METHODS

A retrospective review of patients' charts and imaging was performed to determine outcomes after anterior cervical spine operations. Specifically, we looked at the need for additional surgery, local reaction to the bioabsorbable polymer, fusion rate, and complications. Procedures involved the C3-C4, C4-C5, C5-C6, and/or C6-C7 levels, and fibular allograft was used in all but one case. The anterior cervical discectomy and fusion procedures with internal fixation were performed in 26 patients between March 2000 and November 2001. The patients were followed for up to 2 years after surgery (average, 14 mo).

RESULTS

Radiographic fusion was achieved in 25 (96.2%) of 26 patients. Only one instance of treatment failure was encountered that required additional surgery and the placement of a titanium plate. There were no clinical signs or symptoms of reaction to the bioabsorbable material.

CONCLUSION

The rates of fusion after single-level anterior cervical discectomy and fusion with internal fixation using bioabsorbable polymer and screws in this study match those using metallic implants, as previously reported in the literature, and are superior to those achieved with noninstrumented fusions. Preliminary results suggest that this newly available technology for anterior fusion is as effective in single-level disease as traditional titanium plating systems. The bioabsorbable material seems to be tolerated well by patients. A larger, randomized, controlled study is necessary to bring the results to statistical significance.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验