Suppr超能文献

分光光度法和荧光法测定药物及尿液样本中的地西泮、溴替唑仑和氯硝西泮。

Spectrophotometric and fluorimetric determination of diazepam, bromazepam and clonazepam in pharmaceutical and urine samples.

作者信息

Salem A A, Barsoum B N, Izake E L

机构信息

Department of Chemistry, Faculty of Science, UAE University, Al-Ain, United Arab Emirates.

出版信息

Spectrochim Acta A Mol Biomol Spectrosc. 2004 Mar;60(4):771-80. doi: 10.1016/S1386-1425(03)00300-7.

Abstract

New spectrophotometric and fluorimetric methods have been developed to determine diazepam, bromazepam and clonazepam (1,4-benzodiazepines) in pure forms, pharmaceutical preparations and biological fluid. The new methods are based on measuring absorption or emission spectra in methanolic potassium hydroxide solution. Fluorimetric methods have proved selective with low detection limits, whereas photometric methods showed relatively high detection limits. Successive applications of developed methods for drugs determination in pharmaceutical preparations and urine samples were performed. Photometric methods gave linear calibration graphs in the ranges of 2.85-28.5, 0.316-3.16, and 0.316-3.16 microgml-1 with detection limits of 1.27, 0.08 and 0.13 microgml-1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 2.60, 5.26 and 3.93 and relative standard deviations (R.S.D.s) of 2.79, 2.12 and 2.83, respectively, were obtained. Fluorimetric methods gave linear calibration graphs in the ranges of 0.03-0.34, 0.03-0.32 and 0.03-0.38 microgml-1 with detection limits of 7.13, 5.67 and 16.47 ngml-1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 0.29, 4.33 and 5.42 and R.S.D.s of 1.27, 1.96 and 1.14 were obtained, respectively. Statistical Students t-test and F-test have been used and satisfactory results were obtained.

摘要

已开发出新的分光光度法和荧光法,用于测定纯品、药物制剂及生物体液中的地西泮、溴西泮和氯硝西泮(1,4 - 苯二氮䓬类药物)。新方法基于在氢氧化钾甲醇溶液中测量吸收光谱或发射光谱。荧光法已证明具有选择性且检测限低,而光度法的检测限相对较高。已将所开发的方法相继应用于药物制剂和尿液样品中药物的测定。光度法在2.85 - 28.5、0.316 - 3.16和0.316 - 3.16 μg/ml-1范围内给出线性校准曲线,地西泮、溴西泮和氯硝西泮的检测限分别为1.27、0.08和0.13 μg/ml-1。分别获得了相应的平均误差2.60、5.26和3.93以及相对标准偏差(R.S.D.s)2.79、2.12和2.83。荧光法在0.03 - 0.34、0.03 - 0.32和0.03 - 0.38 μg/ml-1范围内给出线性校准曲线,地西泮、溴西泮和氯硝西泮的检测限分别为7.13、5.67和16.47 ng/ml-1。分别获得了相应的平均误差0.29、4.33和5.42以及R.S.D.s 1.27、1.96和1.14。已使用统计学学生t检验和F检验,并获得了满意的结果。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验