Suppr超能文献

分光光度法和荧光法测定药物及尿液样本中的地西泮、溴替唑仑和氯硝西泮。

Spectrophotometric and fluorimetric determination of diazepam, bromazepam and clonazepam in pharmaceutical and urine samples.

作者信息

Salem A A, Barsoum B N, Izake E L

机构信息

Department of Chemistry, Faculty of Science, UAE University, Al-Ain, United Arab Emirates.

出版信息

Spectrochim Acta A Mol Biomol Spectrosc. 2004 Mar;60(4):771-80. doi: 10.1016/S1386-1425(03)00300-7.

Abstract

New spectrophotometric and fluorimetric methods have been developed to determine diazepam, bromazepam and clonazepam (1,4-benzodiazepines) in pure forms, pharmaceutical preparations and biological fluid. The new methods are based on measuring absorption or emission spectra in methanolic potassium hydroxide solution. Fluorimetric methods have proved selective with low detection limits, whereas photometric methods showed relatively high detection limits. Successive applications of developed methods for drugs determination in pharmaceutical preparations and urine samples were performed. Photometric methods gave linear calibration graphs in the ranges of 2.85-28.5, 0.316-3.16, and 0.316-3.16 microgml-1 with detection limits of 1.27, 0.08 and 0.13 microgml-1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 2.60, 5.26 and 3.93 and relative standard deviations (R.S.D.s) of 2.79, 2.12 and 2.83, respectively, were obtained. Fluorimetric methods gave linear calibration graphs in the ranges of 0.03-0.34, 0.03-0.32 and 0.03-0.38 microgml-1 with detection limits of 7.13, 5.67 and 16.47 ngml-1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 0.29, 4.33 and 5.42 and R.S.D.s of 1.27, 1.96 and 1.14 were obtained, respectively. Statistical Students t-test and F-test have been used and satisfactory results were obtained.

摘要

已开发出新的分光光度法和荧光法,用于测定纯品、药物制剂及生物体液中的地西泮、溴西泮和氯硝西泮(1,4 - 苯二氮䓬类药物)。新方法基于在氢氧化钾甲醇溶液中测量吸收光谱或发射光谱。荧光法已证明具有选择性且检测限低,而光度法的检测限相对较高。已将所开发的方法相继应用于药物制剂和尿液样品中药物的测定。光度法在2.85 - 28.5、0.316 - 3.16和0.316 - 3.16 μg/ml-1范围内给出线性校准曲线,地西泮、溴西泮和氯硝西泮的检测限分别为1.27、0.08和0.13 μg/ml-1。分别获得了相应的平均误差2.60、5.26和3.93以及相对标准偏差(R.S.D.s)2.79、2.12和2.83。荧光法在0.03 - 0.34、0.03 - 0.32和0.03 - 0.38 μg/ml-1范围内给出线性校准曲线,地西泮、溴西泮和氯硝西泮的检测限分别为7.13、5.67和16.47 ng/ml-1。分别获得了相应的平均误差0.29、4.33和5.42以及R.S.D.s 1.27、1.96和1.14。已使用统计学学生t检验和F检验,并获得了满意的结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验