Altura B T, Shirey T L, Young C C, Hiti J, Dell'Orfano K, Handwerker S M, Altura B M
Department of Physiology, State University of New York, Health Science Center, Brooklyn.
Methods Find Exp Clin Pharmacol. 1992 May;14(4):297-304.
A novel ion selective electrode (ISE) for ionized magnesium (IMg2+) in whole blood (WB), plasma (PL) and serum (S) has now been designed and characterized in normal human subjects, diseased and pregnant subjects. Using this ISE on various levels of aqueous Mg2+ solutions (0.1-3.0mM), mean Mg2+ values are within 94.6 and 99.2% of their targets. The linearity of the ISE (0.1-3.0mM) in aqueous solution and human PL and S ranges between 92.0 and 99.3%. The ISE is highly selective for IMg2+, yielding measurements in less than 2 min, and exhibiting no or negligible effects from physiologic concentrations of Ca2+,Na+,K+ or H+. Ligand binding studies indicate that pathophysiologic concentrations of most smaller molecular weight anions fail to interfere with IMg2+ measurements in aqueous solution, PL or S. Likewise, pathophysiologic concentrations of heavy metals or lipids do not interfere with measurements for IMg2+. Comparison of healthy, normal WB, PL and S IMg2+, using the ISE, with measurements of ultrafilterable Mg by atomic absorption spectroscopy (AAS) are excellent. The mean value for IMg2+ in normal WB, PL and S is 0.58-0.60mM (range = 0.53-0.67mM). Compared to total Mg (TMg) (0.75-0.96mM) and ICa2+ (1.10-1.30mM), IMg2+ is held in a narrow, tight range, representing 71% of TMg. Preliminary studies on plasma and serum IMg2+ during open heart surgery and term pregnancy demonstrate significant abnormalities in IMg2+ and % IMg2+. The new ISE for IMg2+ should prove invaluable and revolutionary in studies of Mg metabolism in both healthy and diseased states.
一种用于全血(WB)、血浆(PL)和血清(S)中离子化镁(IMg2+)的新型离子选择性电极(ISE)现已设计完成,并在正常人类受试者、患病受试者和孕妇中进行了特性研究。在不同浓度的Mg2+水溶液(0.1 - 3.0mM)中使用该ISE,Mg2+的平均测量值在其目标值的94.6%至99.2%范围内。ISE在水溶液以及人体血浆和血清中的线性范围(0.1 - 3.0mM)为92.0%至99.3%。该ISE对IMg2+具有高度选择性,测量时间不到2分钟,并且不受生理浓度的Ca2+、Na+、K+或H+的影响或影响可忽略不计。配体结合研究表明,大多数较小分子量阴离子的病理生理浓度不会干扰水溶液、血浆或血清中IMg2+的测量。同样,重金属或脂质的病理生理浓度也不会干扰IMg2+的测量。使用ISE对健康、正常的全血、血浆和血清中的IMg2+进行测量,并与通过原子吸收光谱法(AAS)测量的可超滤镁进行比较,结果非常理想。正常全血、血浆和血清中IMg2+的平均值为0.58 - 0.60mM(范围 = 0.53 - 0.67mM)。与总镁(TMg)(0.75 - 0.96mM)和离子化钙(ICa2+)(1.10 - 1.30mM)相比,IMg2+保持在一个狭窄、稳定的范围内,占TMg的71%。对心脏直视手术和足月妊娠期间血浆和血清中IMg2+的初步研究表明,IMg2+和IMg2+百分比存在显著异常。这种用于IMg2+的新型ISE在健康和疾病状态下镁代谢的研究中应被证明具有极高的价值和革命性。