Suppr超能文献

采用液相色谱-串联质谱法测定人血清中的邻苯二甲酸二(2-乙基己基)酯和邻苯二甲酸单(2-乙基己基)酯。

Determination of di(2-ethylhexyl)phthalate and mono(2-ethylhexyl)phthalate in human serum using liquid chromatography-tandem mass spectrometry.

作者信息

Takatori S, Kitagawa Y, Kitagawa M, Nakazawa H, Hori S

机构信息

Osaka Prefectural Institute of Public Health, 3-69, 1-chome, Nakamichi, Higashinari-ku, Osaka 537-0025, Japan.

出版信息

J Chromatogr B Analyt Technol Biomed Life Sci. 2004 May 25;804(2):397-401. doi: 10.1016/j.jchromb.2004.01.056.

Abstract

Concentrations of mono(2-ethylhexyl)phthalate (MEHP), and di(2-ethylhexyl)phthalate (DEHP), in serum of healthy volunteers were determined by high performance liquid chromatography (HPLC) with tandem mass spectrometry (LC/MS/MS). The serum was extracted with acetone, followed by hexane extraction under acidic conditions, and then applied to the LC/MS/MS. Recoveries of 20 ng/ml of MEHP and DEHP were 101+/-5.7 (n=6) and 102+/-6.5% (n=6), respectively. The limits of quantification (LOQ) of MEHP and DEHP in the method were 5.0 and 14.0 ng/ml, respectively. The concentration of MEHP in the serum was at or less than the LOQ. The concentration of DEHP in the serum was less than the LOQ. Contaminations of MEHP and DEHP from experimental reagents, apparatus and air during the procedure were less than the LOQ and were estimated to be <1.0 and 2.2+/-0.6 ng/ml, respectively. After subtraction of the contamination, the net concentrations of MEHP and DEHP in the serum were estimated at or <5 and <2 ng/ml, respectively. To decrease contamination by DEHP, the cleanup steps and the apparatus and solvent usage were minimized in the sample preparation procedures. The high selectivity of LC/MS/MS is the key for obtaining reliable experimental data from in the matrix-rich analytical samples and for maintaining a low level contamination of MEHP and DEHP in this experimental system. This method would be a useful tool for the detection of MEHP and DEHP in serum.

摘要

采用高效液相色谱-串联质谱法(HPLC-LC/MS/MS)测定健康志愿者血清中邻苯二甲酸单(2-乙基己基)酯(MEHP)和邻苯二甲酸二(2-乙基己基)酯(DEHP)的浓度。血清先用丙酮萃取,然后在酸性条件下用己烷萃取,再进行LC/MS/MS分析。20 ng/ml的MEHP和DEHP的回收率分别为101±5.7%(n=6)和102±6.5%(n=6)。该方法中MEHP和DEHP的定量限(LOQ)分别为5.0和14.0 ng/ml。血清中MEHP的浓度等于或低于LOQ。血清中DEHP的浓度低于LOQ。实验过程中实验试剂、仪器和空气对MEHP和DEHP的污染低于LOQ,估计分别<1.0和2.2±0.6 ng/ml。扣除污染后,血清中MEHP和DEHP的净浓度估计分别等于或<5和<2 ng/ml。为减少DEHP的污染,在样品制备过程中尽量减少净化步骤、仪器和溶剂的使用。LC/MS/MS的高选择性是从富含基质的分析样品中获得可靠实验数据以及在该实验系统中保持MEHP和DEHP低水平污染的关键。该方法将是检测血清中MEHP和DEHP的有用工具。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验