Suppr超能文献

微创动力髋螺钉:标准动力固定装置两种置入技术的前瞻性随机试验

Minimally invasive dynamic hip screw: prospective randomized trial of two techniques of insertion of a standard dynamic fixation device.

作者信息

Alobaid A, Harvey E J, Elder G M, Lander P, Guy P, Reindl R

机构信息

Department of Orthopaedic Surgery, Montreal General Hospital, 1650 Cedar Avenue, Montreal, Quebec H3G 1A4, Canada.

出版信息

J Orthop Trauma. 2004 Apr;18(4):207-12. doi: 10.1097/00005131-200404000-00003.

Abstract

OBJECTIVE

This study evaluates the safety and outcome of a minimally invasive technique for inserting a standard dynamic hip screw for intertrochanteric fractures.

HYPOTHESIS

The use of standard plate in a minimally invasive technique is both possible and advantageous to patient outcome.

DESIGN AND METHODS

Prospective surgeon-randomized blinded outcome clinical study comparing new technique to conventional technique.

MAIN OUTCOME MEASURE

Pain, operative time and mean hemoglobin drop in percutaneous hip fixation.

RESULTS

The minimally invasive technique had significantly less blood loss (P < 0.001), operative time (P < 0.001) and a trend to less morphine use.

CONCLUSIONS

Minimal invasive technique significantly reduces blood loss and operative time for fixation of intertrochanteric hip fractures without sacrifice of fixation stability or bone healing.

摘要

目的

本研究评估采用微创技术插入标准动力髋螺钉治疗股骨转子间骨折的安全性及治疗效果。

假设

在微创技术中使用标准钢板对患者治疗效果而言是可行且有益的。

设计与方法

一项前瞻性的、由外科医生随机分组的、结果盲法的临床研究,将新技术与传统技术进行比较。

主要观察指标

经皮髋部固定术中的疼痛、手术时间及平均血红蛋白下降情况。

结果

微创技术的失血量显著更少(P < 0.001),手术时间显著更短(P < 0.001),且使用吗啡的量有减少趋势。

结论

微创技术可显著减少股骨转子间髋部骨折固定术的失血量及手术时间,且不影响固定稳定性或骨愈合。