Suppr超能文献

一种使用荧光微量检测技术的胰岛素“混合读取”检测方法。

A "mix and read" assay for insulin using fluorometric microvolume assay technology.

作者信息

Toney Jeffrey H, Ogawa Aimie, Blair Megan, Park Young-Whan

机构信息

Metabolic Disorders-Diabetes, Merck Research Laboratories, Rahway, NJ 07065-0900, USA.

出版信息

Assay Drug Dev Technol. 2003 Aug;1(4):521-5. doi: 10.1089/154065803322302772.

Abstract

We describe a novel, "mix and read" immunoassay for insulin in biological samples using FMAT. Current commercial assays for insulin require multiple washing steps and can be expensive. The insulin assay described is a simple two-step, time-saving assay and amenable to robotics. The linear response for the fluorometric signal is comparable to that observed using classical ELISA and RIA. A series of mouse plasma samples were tested for insulin levels and yielded results comparable to that measured using a commercial ELISA for insulin.

摘要

我们描述了一种使用荧光微球自动检测技术(FMAT)对生物样品中的胰岛素进行检测的新型“混合读取”免疫分析方法。目前用于胰岛素检测的商业分析方法需要多个洗涤步骤,且成本可能较高。所描述的胰岛素检测方法是一种简单的两步法,省时且适用于机器人操作。荧光信号的线性响应与使用经典酶联免疫吸附测定法(ELISA)和放射免疫测定法(RIA)所观察到的相当。对一系列小鼠血浆样品进行了胰岛素水平检测,所得结果与使用商业胰岛素ELISA测定法测得的结果相当。