Suppr超能文献

使用流化床气溶胶发生器以固定比例制备两种物质的粉尘混合物用于吸入毒性研究。

Use of fluidizing bed aerosol generators to establish a dust mixture of two substances at a fixed ratio for inhalation toxicity studies.

作者信息

Shiotsuka R N, Kutzman R S, Firriolo J M, Drew R T

机构信息

Medical Department, Brookhaven National Laboratory, Upton, NY 11973.

出版信息

Am Ind Hyg Assoc J. 1992 Aug;53(8):510-3. doi: 10.1080/15298669291360049.

Abstract

A method was developed to use two fluidizing bed generators to deliver a mixture of 1 mg cobalt + 15 mg tungsten carbide/m3 to an inhalation exposure chamber with the output from the cobalt generator split to provide the same cobalt concentration to a cobalt-only chamber. To provide a more uniform delivery of material and to minimize the amount of starting dust needed, a subsystem that produced timed bursts of compressed air was used to prevent the accumulation of dust along the aerosol transport tubes. The addition of an electrostatic precipitator placed in the exhaust lines reduced the amount of dust delivered to the high-efficiency particulate air filters, thereby reducing the number of filter changes.

摘要

开发了一种方法,使用两个流化床发生器将1毫克钴+15毫克碳化钨/立方米的混合物输送到吸入暴露室,同时将钴发生器的输出分流,以便向仅含钴的腔室提供相同的钴浓度。为了实现更均匀的物料输送,并尽量减少所需的起始粉尘量,使用了一个产生定时压缩空气脉冲的子系统,以防止粉尘在气溶胶输送管中积聚。在排气管路中添加静电除尘器,减少了输送到高效空气过滤器的粉尘量,从而减少了过滤器更换的次数。