Suppr超能文献

使用膨体聚四氟乙烯囊袋将诺瓦科尔心室辅助系统置于腹腔内。

Intraabdominal placement of a Novacor ventricular assist system by using an expanded polytetrafluoroethylene pouch.

作者信息

Matsumiya Goro, Miyamoto Yuji, Fukushima Norihide, Monta Osamu, Sawa Yoshiki, Matsuda Hikaru

机构信息

Department of Surgery, Division of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.

出版信息

Ann Thorac Surg. 2004 May;77(5):1851-3. doi: 10.1016/j.athoracsur.2003.07.016.

Abstract

The location of the pump pocket for the left ventricular assist system is of great importance because of its direct relation to subsequent complications. The Novacor device has usually been implanted at the space behind the rectus muscle, which leads to occasional bleeding from raw muscle surfaces and to subsequent pocket infection. Although intraabdominal placement causes less bleeding and is more refractory to later pocket infection, direct contact with the visceral organs sometimes causes serious complications. We constructed a pouch from an expanded polytetrafluoroethylene sheet, and this enabled intraabdominal placement of the Novacor device.

摘要

左心室辅助系统的泵袋位置非常重要,因为它与随后的并发症直接相关。诺瓦科尔装置通常植入腹直肌后方的间隙,这会导致肌肉创面偶尔出血并引发随后的泵袋感染。尽管腹腔内植入出血较少且对后期泵袋感染更具抵抗力,但与内脏器官直接接触有时会导致严重并发症。我们用膨体聚四氟乙烯片构建了一个袋囊,这使得诺瓦科尔装置能够植入腹腔。

相似文献

1
Intraabdominal placement of a Novacor ventricular assist system by using an expanded polytetrafluoroethylene pouch.
Ann Thorac Surg. 2004 May;77(5):1851-3. doi: 10.1016/j.athoracsur.2003.07.016.
2
Use of an intraperitoneal ventricular assist device with a polytetrafluoroethylene barrier decreases infections.
J Heart Lung Transplant. 2008 Mar;27(3):268-71. doi: 10.1016/j.healun.2007.12.004.
3
Modified method for Novacor left ventricular assist device implantation.
Ann Thorac Surg. 1996 Jan;61(1):247-9. doi: 10.1016/0003-4975(95)00943-4.
4
Abdominal fascial enlargement to relieve obstruction of the duodenum caused by Novacor left ventricular assist system.
J Heart Lung Transplant. 2007 Jul;26(7):759-62. doi: 10.1016/j.healun.2007.05.003.
5
Implantation technique for the Novacor left ventricular assist system.
J Thorac Cardiovasc Surg. 1994 Oct;108(4):604-8.
6
Preperitoneal insertion of the HeartMate 1000 IP implantable left ventricular assist device.
Ann Thorac Surg. 1994 Mar;57(3):634-7; discussion 637-8. doi: 10.1016/0003-4975(94)90557-6.
7
Placement of long-term implantable ventricular assist devices without the use of cardiopulmonary bypass.
J Heart Lung Transplant. 2008 Jul;27(7):718-21. doi: 10.1016/j.healun.2008.03.020. Epub 2008 Jun 6.
8
Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.
J Thorac Cardiovasc Surg. 2007 Mar;133(3):689-95. doi: 10.1016/j.jtcvs.2006.08.104.
9
Operative strategies to reduce complications in Novacor left ventricular assist device placement.
J Card Surg. 2004 Jul-Aug;19(4):329-35. doi: 10.1111/j.0886-0440.2004.04097.x.
10
Human clinical fitting study of the DexAide right ventricular assist device.
Artif Organs. 2009 Jul;33(7):558-61. doi: 10.1111/j.1525-1594.2009.00741.x.

引用本文的文献

1
Colonic fistula caused by remaining inflow cannula 14 years after left ventricular assist device explantation.
J Artif Organs. 2018 Sep;21(3):356-358. doi: 10.1007/s10047-018-1016-7. Epub 2018 Jan 12.
2
Prediction of outcome in patients with liver dysfunction after left ventricular assist device implantation.
J Artif Organs. 2013 Dec;16(4):404-10. doi: 10.1007/s10047-013-0724-2. Epub 2013 Aug 29.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验