Suppr超能文献

Quantifying retinal nerve fiber layer thickness histologically: a novel approach to sectioning of the retina.

作者信息

Blumenthal Eytan Z

机构信息

Department of Ophthalmology, Hebrew University, Hadassah Medical Center, Jerusalem, Israel.

出版信息

Invest Ophthalmol Vis Sci. 2004 May;45(5):1404-9. doi: 10.1167/iovs.03-0744.

Abstract

PURPOSE

To present a technique of ocular sectioning that enables continuous histologic measurements of peripapillary retinal nerve fiber layer (RNFL) thickness in a concentric ring around the optic disc, corresponding to similar regions measured by in vivo imaging techniques.

METHODS

Two pig eyes and two normal human eyes were processed using the "umbrella" technique, in which peripapillary concentric ring sections were obtained, at increasing diameters, all centered on the optic disc. Each histologic ring section contains a continuous circumferential 360 degrees retinal slice, oriented approximately perpendicular to the retinal surface. Every histologic slice contains each axon of the retina, sectioned perpendicular to each axon's long axis and at an equal set distance from the disc margin.

RESULTS

Ring sections from pig and human eyes are presented and correlated to known RNFL anatomy. For the two human eyes, peripapillary RNFL thickness was quantified and plotted, resulting in the expected double-hump pattern.

CONCLUSIONS

The umbrella technique provides, on a single histologic section, all necessary information for quantifying the entire RNFL layer of that eye, in a standardized fashion. This technique can simplify the process of analyzing the RNFL thickness histologically, assist in obtaining a normative database of RNFL thickness in humans, and be implemented as a histologic end point in animal studies evaluating new treatment modalities for glaucoma.