Med Pr. 2004;55(1):55-62.

Abstract

In 2001, the legal regulation on maximum admissible intensities (MAI) of electromagnetic fields (EMF) in the frequency range of 0-300 GHz was amended. In the existing regulation, the ranges for frequencies between 0 and 50 Hz and between 50 Hz and 1 kHz were not defined, and for the frequency of 50 Hz there were no regulations for the electric component. The amended regulation expands the obligation to measure and assess the magnetic component up to 3 GHz (formerly to 10 MHz only) and moderates the admissible level for extremities at the frequency below 800 kHz (magnetic component). In addition, the MAI values are thoroughly verified in the whole range of standardized frequencies. Formally, all kinds of power supplied equipment are the source of EMF. In practice, the measurement of all equipment and installations is not feasible or justified. According to the Database by the Chief Sanitary Inspector, the number of EMF sources recorded by the sanitary inspection in 2002 exceeded 60 thousand. Therefore, it was found advisable to analyze the results obtained from the studies of occupational exposure to EMF after the introduction of new MAI'2001 to select equipment and to find out whether equipment and installations generating EMF corresponding at most with protective zone needs to be controlled. The analysis covered 9 thousand of equipment and installations of various types (data collected by the Central Database on EMF sources and our own data), in particular EMF sources: strong EMF with endangered protective zone and non-identified levels of generated EMF; weak EMF but responsible for chronic exposure; and EMF sources occurring in large quantities in places where people work or have to stay longer (e.g., hospitals, treatment rooms, production halls). The analysis facilitated the hygienic evaluation of the equipment and installations according to MAI'2001. In all, 49% of equipment were found not to be the source of EMF with values from protective zones, and thus it is obvious that their control is not justified as exposure does not occur or in case of occupational exposure it can be neglected. The authors present a long list of equipment and installations with the maximum levels of generated EMF. The level of generated EMF was assessed according to the criterion of protective zones: intermediate, hazardous and dangerous.

摘要

2001年,对0至300吉赫兹频率范围内电磁场(EMF)的最大允许强度(MAI)的法律法规进行了修订。在现行法规中,未定义0至50赫兹以及50赫兹至1千赫兹之间的频率范围,并且对于50赫兹的频率,没有关于电分量的规定。修订后的法规将测量和评估磁分量的义务扩展至3吉赫兹(以前仅至10兆赫兹),并放宽了800千赫兹以下频率时四肢的允许水平(磁分量)。此外,在整个标准频率范围内对MAI值进行了全面验证。从形式上讲,各类供电设备都是EMF的来源。但在实际中,对所有设备和装置进行测量并不可行或不合理。根据首席卫生检查员的数据库,2002年卫生检查记录的EMF源数量超过6万。因此,人们认为在引入新的2001年MAI后,分析从职业性EMF暴露研究中获得的结果以选择设备,并查明是否需要控制那些产生的EMF至多符合保护区要求的设备和装置是明智的。该分析涵盖了9000台各类设备和装置(由中央EMF源数据库收集的数据以及我们自己的数据),特别是EMF源:具有濒危保护区且EMF产生水平不明的强EMF;弱EMF但会导致慢性暴露;以及在人们工作或必须长时间停留的地方大量出现的EMF源(例如医院、治疗室、生产车间)。该分析有助于根据2001年MAI对设备和装置进行卫生评估。总体而言,发现49%的设备不是保护区值EMF的来源,因此很明显,由于不会发生暴露或在职业暴露情况下可以忽略,对其进行控制是不合理的。作者列出了一长串产生EMF最高水平的设备和装置。根据保护区标准评估产生的EMF水平:中级、危险和极度危险。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验