Llorente Lourdes, Barbero Sergio, Merayo Jesus, Marcos Susana
Instituto de Optica "Daza de Valdes", Consejo Superior de Investigaciones Cientificas, Madrid, Spain.
J Refract Surg. 2004 May-Jun;20(3):203-16. doi: 10.3928/1081-597X-20040501-03.
To evaluate changes induced by standard laser in situ keratomileusis (LASIK) for hyperopia on total and corneal optical quality.
Total and corneal aberrations were measured before and after standard hyperopic LASIK in 13 eyes (preoperative spherical equivalent refractive error +3.17 +/- 1.10 D). The Chiron Technolas 217C laser with PlanoScan was used. Total aberrations (measured using laser ray tracing) and corneal aberrations (estimated from a videokeratoscope) were described using Zernike terms. Root-mean-square wavefront error for both total and corneal aberrations, and through-focus Strehl ratio for the point spread function of the whole eye were used to assess optical changes induced by surgery.
Third and higher order aberrations increased significantly after hyperopic LASIK (by a factor of 2.20 for total and 1.78 for corneal aberrations, for a 6.5-mm pupil). Spherical aberration changed to negative values (corneal average decreased by -0.85 +/- 0.48 microm and total average by -0.70 +/- 0.30 microm). Best Strehl ratio for the whole eye decreased by a factor of 1.84. Hyperopic LASIK induced larger changes than myopic LASIK, compared to an equivalent group of myopic eyes from a previous study. Induced corneal spherical aberration was six times larger after hyperopic LASIK, for a similar range of correction, and of opposite sign. As with myopic LASIK, changes in internal spherical aberration are of opposite sign to those induced on the corneal anterior surface.
Hyperopic LASIK induced significant amounts of aberrations. The largest increase occurred in spherical aberration, which showed a shift (toward negative values) of opposite sign; increase was greater than for myopic LASIK.
评估标准准分子原位角膜磨镶术(LASIK)治疗远视对全眼和角膜光学质量的影响。
对13只眼(术前等效球镜屈光不正为+3.17±1.10 D)进行标准远视性LASIK手术,测量手术前后的全眼和角膜像差。使用配备PlanoScan的Chiron Technolas 217C激光。用泽尼克项描述全眼像差(使用激光光线追迹测量)和角膜像差(通过角膜地形图仪估算)。用全眼和角膜像差的均方根波前误差以及全眼点扩散函数的聚焦 Strehl 比率评估手术引起的光学变化。
远视性LASIK术后三阶及更高阶像差显著增加(6.5 mm瞳孔直径时,全眼像差增加2.20倍,角膜像差增加1.78倍)。球差变为负值(角膜平均减少-0.85±0.48 µm,全眼平均减少-0.70±0.30 µm)。全眼最佳 Strehl 比率降低了1.84倍。与先前研究中一组等效的近视眼睛相比,远视性LASIK引起的变化比近视性LASIK更大。在相似的矫正范围内,远视性LASIK术后诱导的角膜球差大6倍,且符号相反。与近视性LASIK一样,内部球差的变化与角膜前表面诱导的变化符号相反。
远视性LASIK引起大量像差。最大的增加发生在球差上,球差显示出相反符号的偏移(向负值);增加幅度大于近视性LASIK。