Ricci Paolo, Intrieri Francesco, Cantisani Vito, Drudi Francesco M, Fasoli Fabrizio, Arduini Federico, Pagliara Elisa, Benedetti Valentini Fabrizio, Passariello Roberto
Dipartimento di Scienze Radiologiche, Università degli Studi di Roma La Sapienza, Policlinico Umberto I, Roma, Italy.
Radiol Med. 2004 May-Jun;107(5-6):506-14.
To assess the feasibility and the accuracy of a new technique in the evaluation of deep venous thrombosis (DVT) in the ilio-caval axis.
Thirty-eight patients with suspected DVT were prospectively examined with unenhanced and enhanced colour-Doppler ultrasonography, and ascending contrast venography. Thirty-five out of 38 patients underwent US phlebography, consisting in manual injection of Levovist (Schering Ag, Berlin, Germany) through a 21-G cannula in a suitable dorsal vein of the foot ipsilateral to the suspected DVT. Three patients in whom it was not possible to cannulate a dorsal vein of foot underwent contrast-enhanced US after injection of Levovist through an antecubital vein, but where excluded from the present study. A contrast venogram was nonetheless carried out in all out three patients for comparison with the US-phlebography findings.
US-phlebography allowed better definition of the presence and extension of deep vein thrombosis in all patients, when compared to conventional color-Doppler US. In the evaluation of suspected acute thrombosis, the comparative efficacy of Doppler-US and US phlebography compared with ascending phlebography as the gold standard, was as follows: sensitivity of 85.7% and 90%, specificity of 71.4 and 100%, accuracy of 80.9 and 95.2%, PPV of 85.7, and 100%, and NPV of 71.4, and 75%, respectively. In the assessment of chronic thrombosis, US and US phlebography achieved a sensitivity of 90% and 100%, a specificity of 75% and 100%, an accuracy of 85.7% and 100%, a PPV of 100, 100%, a NPV of 87.5, 100%, respectively. No complications related to US phlebography were observed.
US-phlebography is a promising tool in the assessment of deep vein thrombosis, being highly accurate and feasible. However, further studies based on larger series are mandatory to confirm our promising results and establish a standardised role for this new technique.