Narayana Chandrashekar, Tripathi Madhavi, Kumar Ajay, Gowda Naveen Krishne, Phom Hentok, Chandra Prem, Bandopadhyaya Gurupad, Bal Chandrasekhar
Department of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India.
Nucl Med Commun. 2004 Jul;25(7):743-7. doi: 10.1097/01.mnm.0000131133.07279.60.
To evaluate whether cortical scars can be detected using the summed images of technetium-99m-L,L-ethylenedicysteine (99mTc-L,L-EC) renal dynamic scan, and to compare the results with technetium-99m-dimercaptosuccinic acid (99mTc-DMSA) scan. To evaluate the inter-observer variability for 99mTc-L,L-EC and 99mTc-DMSA scan reporting.
One hundred and three patients were initially included in the study; 21 were excluded, five due to a single functioning kidney and 16 due to impaired renal function (serum creatinine>2.5 mg.dl(-1)). Eighty-two patients (39 females, 43 males), including 31 children, with a mean age of 33.4+/-11.3 years (range, 4 months to 74 years), underwent both 99mTc-DMSA and 99mTc-L,L-EC scintigraphy within a period of 14 days. 99mTc-L,L-EC images were regrouped into 2 min image sets, and the initial 2 min summed image (cortical phase) was used for the evaluation of scars. Three independent observers analysed both images separately on different days without being aware of the identity and clinical details of the patients. Their 99mTc-L,L-EC findings were compared with the consensus 99mTc-DMSA scan findings taken as reference.
The overall sensitivity of 99mTc-L,L-EC scans was 93% and the specificity was 96%. The inter-observer variability was 0.91 for 99mTc-L,L-EC and 0.94 for 99mTc-DMSA scan reporting, using the weighted kappa analysis at P<0.05.
99mTc-L,L-EC is an excellent single-modality comprehensive investigational agent for renal morphology, function and outflow tract evaluation with the added advantages of lower cost, convenience and low radiation exposure to the patient.
评估利用锝-99m-L,L-乙二巯基丁二酸(99mTc-L,L-EC)肾动态扫描的叠加图像能否检测出皮质瘢痕,并将结果与锝-99m-二巯基丁二酸(99mTc-DMSA)扫描结果进行比较。评估99mTc-L,L-EC和99mTc-DMSA扫描报告的观察者间变异性。
103例患者最初纳入本研究;21例被排除,5例因单肾有功能,16例因肾功能受损(血清肌酐>2.5mg·dl⁻¹)。82例患者(39例女性,43例男性),包括31例儿童,平均年龄33.4±11.3岁(范围4个月至74岁),在14天内接受了99mTc-DMSA和99mTc-L,L-EC闪烁扫描。99mTc-L,L-EC图像被重新组合为2分钟图像集,并使用最初的2分钟叠加图像(皮质期)评估瘢痕。三名独立观察者在不同日期分别分析这两种图像,且不知道患者的身份和临床细节。将他们的99mTc-L,L-EC检查结果与作为参考的99mTc-DMSA扫描的一致结果进行比较。
99mTc-L,L-EC扫描的总体敏感性为93%,特异性为96%。使用P<0.05的加权kappa分析,99mTc-L,L-EC扫描报告的观察者间变异性为0.91,99mTc-DMSA扫描报告的观察者间变异性为0.94。
99mTc-L,L-EC是一种用于肾形态、功能和流出道评估的优秀单模态综合检查剂,具有成本较低、方便和患者辐射暴露低等额外优势。